EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Wearable K Band Sensors for Telemonitoring and Telehealth and Telemedicine Systems

Albert Sabban iD

Sensors · 2025

DOI: 10.3390/s25185707 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Albert Sabban. Beteiligte Einrichtung: Department of Electrical Engineering, Braude College of Engineering, Karmi 2161002, Israel. Hauptthemen laut MEDLINE: Telemedicine, Wearable Electronic Devices. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Novel K band wearable sensors and antennas for Telemonitoring, Telehealth and Telemedicine Systems, Internet of Things (IoT) systems, and communication sensors are discussed in this paper. Only in a limited number of papers are K band sensors presented. One of the major goals in the evaluation of Telehealth and Telemedicine and wireless communication devices is the development of efficient compact low-cost antennas and sensors. The development of wideband efficient antennas is crucial to the evaluation of wideband and multiband efficient Telemonitoring, Telehealth and Telemedicine wearable devices. The advantage of the printed wearable antenna is that the feed and matching network can be etched on the same substrate as the printed radiating antenna. K band slot antennas and arrays are presented in this paper the sensors are compact, lightweight, efficient, and wideband. The antennas’ design parameters, and comparison between computation and measured electrical performance of the antennas, are presented in this paper. Fractal efficient antennas and sensors were evaluated to maximize the electrical characteristics of the communication and medical devices. This paper presents wideband printed antennas in frequencies from 16 GH to 26 GHz for Telemonitoring, Telehealth and Telemedicine Systems. The bandwidth of the K band fractal slot antennas and arrays ranges from 10% to 40%. The electrical characteristics of the new compact antennas in the vicinity of the patient body were measured and simulated by using electromagnetic simulation techniques. The gain of the new K band fractal antennas and slot arrays presented in this paper ranges from 3 dBi to 7.5 dBi with 90% efficiency.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TelemedicineWearable Electronic DevicesHumansWireless TechnologyMonitoring, PhysiologicEquipment DesignInternet of Things

Stichwörter der Autor:innen

K bandantennasfractal antennastelemedicinetelemonitoringwearable sensors

Autor:innen und Institutionen

  • Department of Electrical Engineering, Braude College of Engineering, Karmi 2161002, Israel.

ORCID-Profile: Albert Sabban

Zitieren

APA

Sabban, A. (2025). Wearable K Band Sensors for Telemonitoring and Telehealth and Telemedicine Systems. Sensors. https://doi.org/10.3390/s25185707

Vancouver

Sabban A. Wearable K Band Sensors for Telemonitoring and Telehealth and Telemedicine Systems. Sensors. 2025. doi:10.3390/s25185707

BibTeX
@article{Sabban2025,
  author = {Sabban, Albert},
  title = {Wearable K Band Sensors for Telemonitoring and Telehealth and Telemedicine Systems},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25185707}
}
Kostenlos starten →