EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validation of Inertial Measurement Units for Measuring Lower-Extremity Kinematics During Squat–Pivot and Stoop–Twist Lifting Tasks

Rutuja A Kulkarni, Rajit Banerjee, Vicki Z Wang iD, Marcel Oliart iD, Verity Rampulla, Prithvi Das, Alicia M Koontz iD

Sensors · 11.09.2025 · 25 (18) · 5673

DOI: 10.3390/s25185673 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 11.09.2025. Verfasst von Rutuja A Kulkarni und 6 weiteren Autor:innen. Beteiligte Einrichtung: Human Engineering Research Laboratories, VA Pittsburgh Healthcare System, Pittsburgh, PA 15206, USA. Hauptthemen laut MEDLINE: Lower Extremity, Lifting. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: RRD VA, United States (U.S.) Department of Veterans Affairs (VA) Rehabilitation Research and Development, VA RR&D Service Research Career Scientist Award.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optokinetic motion capture (OMC) is the gold standard for measuring the kinematics associated with lifting posture. Unfortunately, limitations exist, including cost, portability, and marker occlusion. The purpose of this study is to evaluate the agreement between OMC and inertial measurement units (IMUs) for quantifying joint kinematics during squat–pivot and stoop–twist lifting tasks. Ten unimpaired adults wearing both IMUs and OMC markers performed 24 lifting trials. Correlation coefficients and Root Mean Square Error (RMSE) between IMU and OMC time-series signals were computed for trunk and lower-extremity joints. Peak values obtained from each system during each trial were analyzed via Bland–Altman plots. Results show high correlations for trunk, knee, and ankle flexion angles (>0.9) and ankle rotation angles (>0.7). Moderate correlation was found for trunk axial rotation and lateral flexion angles (0.5–0.7). RMSE was under 9° for each angle. Biases between systems ranged from 0.3° to 16°. Both systems were able to detect statistically significant differences in peak angles between the two postures (p < 0.05). IMUs show promise for recording field data on complex lifting tasks.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lower ExtremityLiftingHumansBiomechanical PhenomenaAdultMaleFemalePostureRange of Motion, ArticularYoung Adult

Stichwörter der Autor:innen

biomechanicsinertial measurement units (IMUs)lifting techniquemotion captureposture

Autor:innen und Institutionen

  • Human Engineering Research Laboratories, VA Pittsburgh Healthcare System, Pittsburgh, PA 15206, USA.
  • Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA 15261, USA.
  • Department of Physical Medicine and Rehabilitation, University of Pittsburgh Medical Center, Pittsburgh, PA 15206, USA.
  • Department of Rehabilitation Science and Technology, University of Pittsburgh, Pittsburgh, PA 15260, USA.

ORCID-Profile: Vicki Z Wang, Marcel Oliart, Alicia M Koontz

Förderung

  • RRD VA
  • United States (U.S.) Department of Veterans Affairs (VA) Rehabilitation Research and Development
  • VA RR&D Service Research Career Scientist Award
  • United States (U.S.) Department of Veterans Affairs (VA) Rehabilitation Research and Development (RR&amp;D) Service
  • VA RR&amp;D Service Research Career Scientist Award

Zitieren

APA

Kulkarni, R. A., Banerjee, R., Wang, V. Z., Oliart, M., Rampulla, V., Das, P., & Koontz, A. M. (2025). Validation of Inertial Measurement Units for Measuring Lower-Extremity Kinematics During Squat–Pivot and Stoop–Twist Lifting Tasks. Sensors, 25(18), 5673. https://doi.org/10.3390/s25185673

Vancouver

Kulkarni RA, Banerjee R, Wang VZ, Oliart M, Rampulla V, Das P, et al. Validation of Inertial Measurement Units for Measuring Lower-Extremity Kinematics During Squat–Pivot and Stoop–Twist Lifting Tasks. Sensors. 2025;25(18):5673. doi:10.3390/s25185673

BibTeX
@article{Kulkarni2025,
  author = {Kulkarni, Rutuja A and Banerjee, Rajit and Wang, Vicki Z and Oliart, Marcel and Rampulla, Verity and Das, Prithvi and Koontz, Alicia M},
  title = {Validation of Inertial Measurement Units for Measuring Lower-Extremity Kinematics During Squat–Pivot and Stoop–Twist Lifting Tasks},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {18},
  pages = {5673},
  doi = {10.3390/s25185673}
}
Kostenlos starten →