Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Yusaku Fujii. Beteiligte Einrichtung: School of Science and Technology, Gunma University, Kiryu 376-8515, Japan. Hauptthemen laut MEDLINE: Smartphone, COVID-19, Masks, Respiratory Protective Devices. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Japan Society for the Promotion of Science, Japan Society for the Promotion of Science (JSPS), KAKENHI Grant-in-Aid for Scientific Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, a prototype system was developed as a potential alternative to lockdown measures against the spread of airborne infectious diseases such as COVID-19. The system integrates real-time estimation functions for respiratory flow and mask leakage into a low-cost powered air-purifying respirator (PAPR) designed for the general public. Using only a single differential-pressure sensor (SDP810) and a controller (Arduino UNO R4 WiFi), the respiratory flow (Q3e) is estimated from the differential pressure (ΔP) and battery voltage (Vb), and both the wearing status and leak status are transmitted to and displayed on a smartphone application. For evaluation, a testbench called the Respiratory Airflow Testbench was constructed by connecting a cylinder–piston drive to a mannequin head to simulate realistic wearing conditions. The estimated respiratory flow Q3e, calculated solely from ΔP and Vb, showed high agreement with the measured flow Q3m obtained from a reference flow sensor, confirming the effectiveness of the estimation algorithm. Furthermore, an automatic leak detection method based on the time-integrated value of Q3e was implemented, enabling the detection of improper wearing. This system thus achieves respiratory flow estimation and leakage detection based only on ΔP and Vb. In the future, it is expected to be extended to applications such as pressure control synchronized with breathing activity and health monitoring based on respiratory and coughing analysis. This platform also has the potential to serve as the foundation of a PAPR Wearing Status Network Management System, which will contribute to societal-level infection control through the networked sharing of wearing status information.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneCOVID-19MasksRespiratory Protective DevicesHumansSARS-CoV-2Equipment DesignPressureAlgorithms

Stichwörter der Autor:innen

Arduino microcontrollerBluetooth Low Energy (BLE)PAPR for everyoneairborne infection controlalternative to lockdowndifferential pressure sensormask leakage detectionpandemic preparednesspowered air-purifying respirator (PAPR)respiratory flow estimationsmartphone interface

Autor:innen und Institutionen

  • School of Science and Technology, Gunma University, Kiryu 376-8515, Japan.

ORCID-Profile: Yusaku Fujii

Förderung

  • The Japan Society for the Promotion of Science
  • Japan Society for the Promotion of Science (JSPS), KAKENHI Grant-in-Aid for Scientific Research

Zitieren

APA

Fujii, Y. (2025). The Real-Time Estimation of Respiratory Flow and Mask Leakage in a PAPR Using a Single Differential-Pressure Sensor and Microcontroller-Based Smartphone Interface in the Development of a Public-Oriented Powered Air-Purifying Respirator as an Alternative to Lockdown Measures. Sensors. https://doi.org/10.3390/s25175340

Vancouver

Fujii Y. The Real-Time Estimation of Respiratory Flow and Mask Leakage in a PAPR Using a Single Differential-Pressure Sensor and Microcontroller-Based Smartphone Interface in the Development of a Public-Oriented Powered Air-Purifying Respirator as an Alternative to Lockdown Measures. Sensors. 2025. doi:10.3390/s25175340

BibTeX
@article{Fujii2025,
  author = {Fujii, Yusaku},
  title = {The Real-Time Estimation of Respiratory Flow and Mask Leakage in a PAPR Using a Single Differential-Pressure Sensor and Microcontroller-Based Smartphone Interface in the Development of a Public-Oriented Powered Air-Purifying Respirator as an Alternative to Lockdown Measures},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25175340}
}
Kostenlos starten →