EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Adsorptive Cathodic Stripping Analysis of Xylazine Within Fouling-Resistant and Nanomaterial-Enhanced Modified Electrode Sensors

Michael C Leopold iD, Charles W Sheppard iD, Joyce E Stern, Arielle Vinnikov iD, Ann H Wemple, Ben H Edelman

Sensors · 2025

DOI: 10.3390/s25175312 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Michael C Leopold und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Gottwald Center for the Sciences, University of Richmond, Richmond, VA 23173, USA. Hauptthemen laut MEDLINE: Xylazine, Electrochemical Techniques, Nanostructures. Die Arbeit nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science Foundation, Floyd D. and Elisabeth S. Gottwald Endowment, Department of Chemistry at the University of Richmond (Puryear-Topham-Gupton-Pierce Funding.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Xylazine (XYL), an FDA-approved veterinary tranquilizer, is being abused both as an opioid adulterant in a street-drug known as “Tranq-dope” and as a date rape drug. Given its now nearly ubiquitous use with fentanyl and fentanyl derivatives across the globe, XYL has become a primary target for researchers seeking to develop portable and cost-effective sensors for its detection. Electrochemical sensors based on the oxidation of XYL, while useful, have limitations due to certain interferents and inherent electrode fouling that render the approach less reliable, especially in certain sample matrices. In this work, modified electrode platforms incorporating layers of multi-walled carbon nanotubes for sensitivity along with semi-permeable polyurethane (PU) layers and host–guest chemistry using β-cyclodextrin for selectivity are deployed for XYL detection using complementary adsorptive cathodic stripping analysis. The modified electrode sensors are optimized to minimize high potentials and maintain fouling resistant capabilities and investigated to better understand the function of the PU layer. The use of adsorptive cathodic stripping differential pulse voltammetry indirectly indicates the presence and concentration of XYL within complex sample media (beverages and synthetic urine). When used in this manner, the modified electrodes exhibited an overall average sensitivity of ~35 (±9) nA/μM toward XYL with a limit of quantification of

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

XylazineElectrochemical TechniquesNanostructuresElectrodesHumansNanotubes, CarbonAdsorptionbeta-CyclodextrinsPolyurethanes

Stichwörter der Autor:innen

adsorptivecathodicfentanylmodified electrodestripping analysisxylazine

Substanzen

XylazineNanotubes, Carbonbeta-CyclodextrinsPolyurethanes

Autor:innen und Institutionen

  • Department of Chemistry, Gottwald Center for the Sciences, University of Richmond, Richmond, VA 23173, USA.

ORCID-Profile: Michael C Leopold, Charles W Sheppard, Arielle Vinnikov

Förderung

  • National Science Foundation
  • Floyd D. and Elisabeth S. Gottwald Endowment
  • Department of Chemistry at the University of Richmond (Puryear-Topham-Gupton-Pierce Funding
  • Department of Chemistry at the University of Richmond (Puryear–Topham–Gupton–Pierce Funding

Zitieren

APA

Leopold, M. C., Sheppard, C. W., Stern, J. E., Vinnikov, A., Wemple, A. H., & Edelman, B. H. (2025). Adsorptive Cathodic Stripping Analysis of Xylazine Within Fouling-Resistant and Nanomaterial-Enhanced Modified Electrode Sensors. Sensors. https://doi.org/10.3390/s25175312

Vancouver

Leopold MC, Sheppard CW, Stern JE, Vinnikov A, Wemple AH, Edelman BH. Adsorptive Cathodic Stripping Analysis of Xylazine Within Fouling-Resistant and Nanomaterial-Enhanced Modified Electrode Sensors. Sensors. 2025. doi:10.3390/s25175312

BibTeX
@article{Leopold2025,
  author = {Leopold, Michael C and Sheppard, Charles W and Stern, Joyce E and Vinnikov, Arielle and Wemple, Ann H and Edelman, Ben H},
  title = {Adsorptive Cathodic Stripping Analysis of Xylazine Within Fouling-Resistant and Nanomaterial-Enhanced Modified Electrode Sensors},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25175312}
}
Kostenlos starten →