Cellular Signal Detection by Hydrogenated Amorphous Silicon Photosensitive Chip with Electroexcitation
Sensors · 23.08.2025 · 25 (17) · 5255
DOI: 10.3390/s25175255 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 23.08.2025. Verfasst von Fengyan Hou und 5 weiteren Autor:innen. Beteiligte Einrichtung: International Research Centre for Nano Handling and Manufacturing of China, Changchun University of Science and Technology, Changchun 130022, China. Hauptthemen laut MEDLINE: Silicon, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation Program of China, National Key R&D Program of China, Zhongshan Science and Technology Program.
Abstract (Originalsprache)
Based on the photoconductive effect of photosensitive films, a designed light pattern was projected onto a hydrogenated amorphous silicon (a-Si:H) photosensitive chip to generate virtual light-induced electrodes for cellular electrical detection. To obtain high-quality cellular signals, this study aims to explore the effect of electrical excitation on a-Si:H photosensitive chip. Firstly, the electrochemical impedance spectroscopy (EIS) and volt-ampere characteristics of the a-Si:H photosensitive chip were characterized. EIS data were fitted to extract equivalent circuit models (ECMs) for both the chip and system. Then analog experiments were performed to verify the ECMs, and the results were consistent with the circuit simulation. Finally, applied alternating current (AC) or direct current (DC) signals to the chip and recorded the electrical signals of the cultured cardiomyocytes on the a-Si:H photosensitive chip. The results demonstrated that applying a high-frequency small AC signal to the chip reduced the background noise of the system by approximately 85.1%, and applying a DC bias increased the amplitude of the detection signal by approximately 142.7%. Consequently, the detection performance of the a-Si:H photosensitive chip for weak bioelectrical signals was significantly enhanced, advancing its applicability in cellular electrophysiological studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- International Research Centre for Nano Handling and Manufacturing of China, Changchun University of Science and Technology, Changchun 130022, China.
- Centre for Opto/Bio-Nano Measurement and Manufacturing, Zhongshan Institute of Changchun University of Science and Technology, Zhongshan 528437, China.
- Ministry of Education Key Laboratory for Cross-Scale Micro and Nano Manufacturing, Changchun University of Science and Technology, Changchun 130022, China.
- Wolfson College, University of Oxford, Oxford OX2 6UD, UK.
- IBEST & IRAC, University of Bedfordshire, Luton LU1 3JU, UK.
ORCID-Profile: M James C Crabbe
Förderung
- National Natural Science Foundation Program of China
- National Key R&D Program of China
- Zhongshan Science and Technology Program
- EU Horizon Europe Program
- Jilin Provincial Science and Technology Program
- "111" Project of China
- China Scholarship Council
- National Key R&D Program of China
Zitieren
APA
Hou, F., Dong, J., Wang, X., Deng, Q., Crabbe, M. J. C., & Wang, Z. (2025). Cellular Signal Detection by Hydrogenated Amorphous Silicon Photosensitive Chip with Electroexcitation. Sensors, 25(17), 5255. https://doi.org/10.3390/s25175255
Vancouver
Hou F, Dong J, Wang X, Deng Q, Crabbe MJC, Wang Z. Cellular Signal Detection by Hydrogenated Amorphous Silicon Photosensitive Chip with Electroexcitation. Sensors. 2025;25(17):5255. doi:10.3390/s25175255
BibTeX
@article{Hou2025,
author = {Hou, Fengyan and Dong, Jianjun and Wang, Xia and Deng, Qiuyang and Crabbe, M James C and Wang, Zuobin},
title = {Cellular Signal Detection by Hydrogenated Amorphous Silicon Photosensitive Chip with Electroexcitation},
journal = {Sensors},
year = {2025},
volume = {25},
number = {17},
pages = {5255},
doi = {10.3390/s25175255}
}
EUVIMED