EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Laser-Induced Graphene on Biocompatible PDMS/PEG Composites for Limb Motion Sensing

Anđela Gavran iD, Marija V Pergal iD, Teodora Vićentić iD, Milena Rašljić Rafajilović iD, Igor A Pašti iD, Marko V Bošković iD, Marko Spasenović iD

Sensors · 2025

DOI: 10.3390/s25175238 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Anđela Gavran und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Microelectronic Technologies, Institute of Chemistry, Technology and Metallurgy-National Institute of the Republic of Serbia, University o…. Hauptthemen laut MEDLINE: Graphite, Polyethylene Glycols, Biocompatible Materials, Dimethylpolysiloxanes. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 84 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science Fund of the Republic of Serbia, Ministry of Science, Technological Development, and Innovation of the Republic of Serbia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The advancement of laser-induced graphene (LIG) has significantly enhanced the development of wearable and flexible electronic devices. Due to its exceptional physical, chemical, and electronic properties, LIG has emerged as a highly effective active material for wearable sensors. However, despite the wide range of materials suitable as precursors for LIG, the scarcity of stretchable and biocompatible polymers amenable to laser graphenization has remained a persistent challenge. In this study, laser-induced graphene (LIG) was fabricated directly on biocompatible and flexible cross-linked PDMS/PEG (with Mn (PEG) = 400 g/mol) composites for the first time, enabling their application in wearable sensors. The addition of PEG compensates for the low carbon content in PDMS, enabling efficient laser graphenization. Laser parameters were systematically optimized to achieve high-quality graphene, and a comprehensive characterization with varying PEG content (10–40 wt.%) was conducted using multiple analytical techniques. Tensile tests revealed that incorporating PEG significantly enhanced elongation at break, reaching 237% for PDMS/40 wt.% PEG while reducing Young’s modulus to 0.25 MPa, highlighting the excellent flexibility of the substrate material. Surface analysis using X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and Raman spectroscopy demonstrated the formation of high-quality few-layer graphene with the fewest defects in PDMS/40 wt.% PEG composites. Nevertheless, the adhesion of electrical contacts to LIG that was directly induced on PDMS/PEG proved to be challenging. To overcome this challenge, we produced devices by means of laser induction on polyimide and transfer to PDMS/PEG. We demonstrate the practical utility of such devices by applying them to monitor limb motion in real time. The sensor showed a stable and repeatable piezoresistive response under multiple bending cycles. These results provide valuable insights into the fabrication of biocompatible LIG-based flexible sensors, paving the way for their broader implementation in medical and sports technologies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphitePolyethylene GlycolsBiocompatible MaterialsDimethylpolysiloxanesLasersWearable Electronic DevicesHumans

Stichwörter der Autor:innen

laser-induced graphenephysicochemical propertiespoly(dimethylsiloxane)poly(ethylene glycol)sensors

Substanzen

GraphitePolyethylene GlycolsBiocompatible MaterialsDimethylpolysiloxanesbaysilon

Autor:innen und Institutionen

  • Center for Microelectronic Technologies, Institute of Chemistry, Technology and Metallurgy-National Institute of the Republic of Serbia, University of Belgrade, 11000 Belgrade, Serbia.
  • Faculty of Physical Chemistry, University of Belgrade, 11000 Belgrade, Serbia.
  • Serbian Academy of Sciences and Arts, 11000 Belgrade, Serbia.

ORCID-Profile: Anđela Gavran, Marija V Pergal, Teodora Vićentić, Milena Rašljić Rafajilović, Igor A Pašti, Marko V Bošković, Marko Spasenović

Förderung

  • Science Fund of the Republic of Serbia
  • Ministry of Science, Technological Development, and Innovation of the Republic of Serbia

Zitieren

APA

Gavran, A., Pergal, M. V., Vićentić, T., Rašljić Rafajilović, M., Pašti, I. A., Bošković, M. V., & Spasenović, M. (2025). Laser-Induced Graphene on Biocompatible PDMS/PEG Composites for Limb Motion Sensing. Sensors. https://doi.org/10.3390/s25175238

Vancouver

Gavran A, Pergal MV, Vićentić T, Rašljić Rafajilović M, Pašti IA, Bošković MV, et al. Laser-Induced Graphene on Biocompatible PDMS/PEG Composites for Limb Motion Sensing. Sensors. 2025. doi:10.3390/s25175238

BibTeX
@article{Gavran2025,
  author = {Gavran, Anđela and Pergal, Marija V and Vićentić, Teodora and Rašljić Rafajilović, Milena and Pašti, Igor A and Bošković, Marko V and Spasenović, Marko},
  title = {Laser-Induced Graphene on Biocompatible PDMS/PEG Composites for Limb Motion Sensing},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25175238}
}
Kostenlos starten →