EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Exploring Difference in Hand–Foot Coordination Ability Among Tennis Players of Different Sport Levels Based on the Correlation Between Lower-Limb Acceleration and Hand Grip Force

Yan Xiao, Jinghui Zhong, Yang Gao, Kebao Zhang iD

Sensors · 19.08.2025 · 25 (16) · 5152

DOI: 10.3390/s25165152 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 19.08.2025. Verfasst von Yan Xiao und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Physical Education and Training, Capital University of Physical Education and Sports, Beijing 100191, China. Hauptthemen laut MEDLINE: Hand Strength, Tennis, Foot, Hand. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To quantify real-time hand–foot coupling in tennis and test whether the coupling pattern differs by playing standard.

Methods

Fifteen nationally certified second-level male athletes and fifteen recreational beginners performed multi-directional swings, alternating forehand–backhand groundstrokes and serve-and-volley sequences while tri-axial ankle acceleration and racket-grip force were synchronously recorded in wearable inertial measurement units (IMUs). Grip metrics (mean force, peak force, force duration) and acceleration magnitudes were analysed with MANOVA and Hedges’ g effect sizes, followed by the Benjamini–Hochberg correction (α = 0.025).

Results

Across tasks, athletes showed higher mean ankle acceleration (standardised mean difference, Hedges’ g) but 45% lower mean grip force (Hedges’ g = −1.28; both p < 0.01). The association between acceleration and grip metrics was moderate-to-strong and negative in athletes (r = −0.62 with mean grip force; r = −0.69 with force duration), whereas beginners exhibited moderate-to-strong positive correlations (r = 0.48–0.73).

Conclusion

We quantified hand–foot coordination in tennis by synchronising tri-axial ankle acceleration with calibrated racket-grip force across three match-realistic tasks. Relative to beginners, athletes demonstrated an inverse coupling between ankle acceleration and grip-force metrics, whereas beginners showed a direct coupling, consistent with our purpose of quantifying coordination via synchronised wearable sensors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hand StrengthTennisFootHandLower ExtremityHumansMaleAccelerationAdultAthletesWearable Electronic DevicesBiomechanical PhenomenaYoung Adult

Stichwörter der Autor:innen

accelerometrygrip forcehand–foot coordinationperformance analysistennis

Autor:innen und Institutionen

  • Institute of Physical Education and Training, Capital University of Physical Education and Sports, Beijing 100191, China.
  • School of Kinesiology and Health, Capital University of Physical Education and Sports, Beijing 100191, China.
  • School of Recreation and Community Sport, Capital University of Physical Education and Sports, Beijing 100191, China.

ORCID-Profile: Kebao Zhang

Zitieren

APA

Xiao, Y., Zhong, J., Gao, Y., & Zhang, K. (2025). Exploring Difference in Hand–Foot Coordination Ability Among Tennis Players of Different Sport Levels Based on the Correlation Between Lower-Limb Acceleration and Hand Grip Force. Sensors, 25(16), 5152. https://doi.org/10.3390/s25165152

Vancouver

Xiao Y, Zhong J, Gao Y, Zhang K. Exploring Difference in Hand–Foot Coordination Ability Among Tennis Players of Different Sport Levels Based on the Correlation Between Lower-Limb Acceleration and Hand Grip Force. Sensors. 2025;25(16):5152. doi:10.3390/s25165152

BibTeX
@article{Xiao2025,
  author = {Xiao, Yan and Zhong, Jinghui and Gao, Yang and Zhang, Kebao},
  title = {Exploring Difference in Hand–Foot Coordination Ability Among Tennis Players of Different Sport Levels Based on the Correlation Between Lower-Limb Acceleration and Hand Grip Force},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {16},
  pages = {5152},
  doi = {10.3390/s25165152}
}
Kostenlos starten →