Mechanosensitivity and Adipose Thickness as Determinants of Pressure to Reach Deep Fasciae in Cervical and Thoracolumbar Regions
Sensors · 2025
DOI: 10.3390/s25165073 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Sílvia Pires und 3 weiteren Autor:innen. Beteiligte Einrichtung: Escola Superior de Saúde do Vale do Ave, Cooperativa de Ensino Superior Politécnico e Universitário, Rua José António Vidal, 81, 4760-409 Vila Nova d…. Hauptthemen laut MEDLINE: Adipose Tissue, Fascia, Cervical Vertebrae. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
We aimed to quantify the mechanical pressure required to reach the deep cervical and thoracolumbar fasciae, to examine its association with pressure pain threshold (PPT) and adipose tissue thickness, and to determine whether PPT and adipose tissue thickness can predict the mechanical pressure needed to reach the fascia.
Methods
Forty-three subjects’ PPT, mechanical pressure and skinfold in the trapezius and lumbar regions were evaluated using an algometer, an ultrasound scanner, and an adipometer. The Wilcoxon test, Student’s t-test, and Pearson and Spearman’s correlation tests were used (p < 0.05).
Results
The values of mechanical pressure in the cervical and lumbar regions were 6.06 ± 0.186 N/cm2 and 5.85 ± 5.280, 7.287 N/cm2, respectively. PPT values were 18.88 ± 0.917 N/cm2, and 46.46 ± 2.408 N/cm2, respectively (p < 0.001), and the adipose tissue thickness values in the cervical and lumbar regions were 0.88 ± 0.675 cm, 1.08 and 1.48 ± 0.069 cm (p < 0.001). There was no correlation between the variables in either region under study.
Conclusions
The mechanical pressure required to reach the deep cervical and thoracolumbar fasciae was similar with an average value of approximately 6 N/cm2, suggesting a consistent mechanical response across these anatomical regions. Mechanosensitivity and subcutaneous adipose tissue thickness did not influence the mechanical pressure needed to access the deep fascial tissue.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Escola Superior de Saúde do Vale do Ave, Cooperativa de Ensino Superior Politécnico e Universitário, Rua José António Vidal, 81, 4760-409 Vila Nova de Famalicão, Portugal.
- H2M-Health and Human Movement Unit, Polytechnic University of Health, Cooperativa de Ensino Superior Politécnico e Universitário, Cooperativa de Responsabilidade Limitada, 4760-409 Vila Nova de Famalicão, Portugal.
- Centre of Research Rehabilitation (CIR), Escola Superior de Saúde, Rua Dr. António Bernardino de Almeida 400, 4200-072 Porto, Portugal.
ORCID-Profile: Sílvia Pires, Marta Freitas, Francisco Pinho, Sofia Brandão
Zitieren
APA
Pires, S., Freitas, M., Pinho, F., & Brandão, S. (2025). Mechanosensitivity and Adipose Thickness as Determinants of Pressure to Reach Deep Fasciae in Cervical and Thoracolumbar Regions. Sensors. https://doi.org/10.3390/s25165073
Vancouver
Pires S, Freitas M, Pinho F, Brandão S. Mechanosensitivity and Adipose Thickness as Determinants of Pressure to Reach Deep Fasciae in Cervical and Thoracolumbar Regions. Sensors. 2025. doi:10.3390/s25165073
BibTeX
@article{Pires2025,
author = {Pires, Sílvia and Freitas, Marta and Pinho, Francisco and Brandão, Sofia},
title = {Mechanosensitivity and Adipose Thickness as Determinants of Pressure to Reach Deep Fasciae in Cervical and Thoracolumbar Regions},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25165073}
}
EUVIMED