Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Francesco Castelli Gattinara Di Zubiena und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Aerospace Engineering, Sapienza University of Rome, 00184 Rome, Italy. Hauptthemen laut MEDLINE: Parkinson Disease, Wearable Electronic Devices, Gait, Gait Disorders, Neurologic. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research activity was supported by the European funding "PNRR-MR1-2022-541 12376921, Next Generation EU (PNRR M6C2) Investment 2.1 Enhancement and strengthenin…, PNRR-MR1-2022-12376921, Next Generation EU (PNRR M6C2) Investment 2.1 Enhancement and strengthening of biomedical research of the NHS.
Abstract (Originalsprache)
Parkinson’s disease (PD) is a disorder that causes a decrease in motor skills. Among the symptoms that have been observed, the most significant is the occurrence of Freezing of Gait (FoG), which manifests as an abrupt cessation of walking. This study investigates the impact of spatiotemporal gait parameters using wearable inertial measurement units (IMUs). Notably, 30 PD patients (15 with FoG, 15 without) and 20 healthy controls were enrolled. Gait data were acquired using two foot-mounted IMUs and key parameters such as stride time, gait phase distribution, cadence, stride length, speed, and foot clearance were extracted. Results indicated a tangible decline in motor abilities in PD patients, especially in those with FoG. Differences were observed in the segmentation of gait phases, with diminished swing phase duration observed in patients, and in the diminished spatial parameters of stride length, velocity, and foot clearance. Additionally, to validate the results, the accuracy of IMU-derived clearance measurements was validated against an optoelectronic system. While the IMUs accurately detected maximum points, the minimum clearance showed a higher measurement error. These findings support the use of wearable IMUs as a reliable and low-cost alternative to laboratory systems for the assessment of gait abnormalities in PD. Moreover, they highlight the potential for early detection and monitoring of FoG in both clinical and home settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical and Aerospace Engineering, Sapienza University of Rome, 00184 Rome, Italy.
- Department of Human Neurosciences, Sapienza University of Rome, 00185 Rome, Italy.
- IRCCS Neuromed, 86077 Pozzilli, Italy.
- Department of Anatomical and Histological Sciences, Legal Medicine and Orthopedics, Sapienza University of Rome, 00185 Rome, Italy.
- Department of Engineering, University Niccolò Cusano, 00166 Rome, Italy.
- Department of Engineering, University of Messina, 98122 Messina, Italy.
ORCID-Profile: Francesco Castelli Gattinara Di Zubiena, Alessandro Zampogna, Giovanni Cusolito, Ludovica Apa, Ilaria Mileti, Antonio Cannuli, Antonio Suppa, Marco Paoloni, Zaccaria Del Prete, Eduardo Palermo
Förderung
- Research activity was supported by the European funding "PNRR-MR1-2022-541 12376921, Next Generation EU (PNRR M6C2) Investment 2.1 Enhancement and strengthenin…
- PNRR-MR1-2022-12376921, Next Generation EU (PNRR M6C2) Investment 2.1 Enhancement and strengthening of biomedical research of the NHS
Zitieren
APA
Castelli Gattinara Di Zubiena, F., Zampogna, A., Patera, M., Cusolito, G., Apa, L., Mileti, I., Cannuli, A., Suppa, A., Paoloni, M., Del Prete, Z., & Palermo, E. (2025). Uncovering the Kinematic Signature of Freezing of Gait in Parkinson’s Disease Through Wearable Inertial Sensors. Sensors. https://doi.org/10.3390/s25165054
Vancouver
Castelli Gattinara Di Zubiena F, Zampogna A, Patera M, Cusolito G, Apa L, Mileti I, et al. Uncovering the Kinematic Signature of Freezing of Gait in Parkinson’s Disease Through Wearable Inertial Sensors. Sensors. 2025. doi:10.3390/s25165054
BibTeX
@article{CastelliGattinaraDiZubiena2025,
author = {Castelli Gattinara Di Zubiena, Francesco and Zampogna, Alessandro and Patera, Martina and Cusolito, Giovanni and Apa, Ludovica and Mileti, Ilaria and Cannuli, Antonio and Suppa, Antonio and Paoloni, Marco and Del Prete, Zaccaria and Palermo, Eduardo},
title = {Uncovering the Kinematic Signature of Freezing of Gait in Parkinson’s Disease Through Wearable Inertial Sensors},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25165054}
}
EUVIMED