Leakage Detection Using Distributed Acoustic Sensing in Gas Pipelines
Sensors · 10.08.2025 · 25 (16) · 4937
DOI: 10.3390/s25164937 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 10.08.2025. Verfasst von Mouna-Keltoum Benabid und 3 weiteren Autor:innen. Beteiligte Einrichtung: Petroleum Engineering Department, Colorado School of Mines, Golden, CO 80401, USA. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Transportation, Department of Transportation Pipeline and Hazardous Materials Safety Administration.
Abstract (Originalsprache)
This study investigates the performance of Distributed Acoustic Sensing (DAS) for detecting gas pipeline leaks under controlled experimental conditions, using multiple fiber cable types deployed both internally and externally. A 21 m steel pipeline with a 1 m test section was configured to simulate leakage scenarios with varying leak sizes (¼”, ½”, ¾”, and 1”), orientations (top, side, bottom), and flow velocities (2–18 m/s). Experiments were conducted under two installation conditions: a supported pipeline mounted on tripods, and a buried pipeline laid on the ground and covered with sand. Four fiber deployment methods were tested: three internal cables of varying geometries and one externally mounted straight cable. DAS data were analyzed using both time-domain vibration intensity and frequency-domain spectral methods. The results demonstrate that leak detectability is influenced by multiple interacting factors, including flow rate, leak size and orientation, pipeline installation method, and fiber cable type and deployment approach. Internally deployed black and flat cables exhibited higher sensitivity to leak-induced vibrations, particularly at higher flow velocities, larger leak sizes, and for bottom-positioned leaks. The thick internal cable showed limited response due to its wireline-like construction. In contrast, the external straight cable responded selectively, with performance dependent on mechanical coupling. Overall, leakage detectability was reduced in the buried configuration due to damping effects. The novelty of this work lies in the successful detection of gas leaks using internally deployed fiber optic cables, which has not been demonstrated in previous studies. This deployment approach is practical for field applications, particularly for pipelines that cannot be inspected using conventional methods, such as unpiggable pipelines.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Petroleum Engineering Department, Colorado School of Mines, Golden, CO 80401, USA.
- Geophysics Department, Colorado School of Mines, Golden, CO 80401, USA.
ORCID-Profile: Mouna-Keltoum Benabid, Ge Jin, Yilin Fan
Förderung
- Department of Transportation
- Department of Transportation Pipeline and Hazardous Materials Safety Administration
Zitieren
APA
Benabid, M. K., Baumgartner, P., Jin, G., & Fan, Y. (2025). Leakage Detection Using Distributed Acoustic Sensing in Gas Pipelines. Sensors, 25(16), 4937. https://doi.org/10.3390/s25164937
Vancouver
Benabid MK, Baumgartner P, Jin G, Fan Y. Leakage Detection Using Distributed Acoustic Sensing in Gas Pipelines. Sensors. 2025;25(16):4937. doi:10.3390/s25164937
BibTeX
@article{Benabid2025,
author = {Benabid, Mouna-Keltoum and Baumgartner, Peyton and Jin, Ge and Fan, Yilin},
title = {Leakage Detection Using Distributed Acoustic Sensing in Gas Pipelines},
journal = {Sensors},
year = {2025},
volume = {25},
number = {16},
pages = {4937},
doi = {10.3390/s25164937}
}
EUVIMED