Dual-Branch Deep Learning with Dynamic Stage Detection for CT Tube Life Prediction
Sensors · 04.08.2025 · 25 (15) · 4790
DOI: 10.3390/s25154790 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 04.08.2025. Verfasst von Zhu Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Engineering, West China Hospital, Sichuan University, Chengdu 610041, China. Hauptthemen laut MEDLINE: Deep Learning, Tomography, X-Ray Computed. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China, National Key R&D Program of China.
Abstract (Originalsprache)
CT scanners are essential tools in modern medical imaging. Sudden failures of their X-ray tubes can lead to equipment downtime, affecting healthcare services and patient diagnosis. However, existing prediction methods based on a single model struggle to adapt to the multi-stage variation characteristics of tube lifespan and have limited modeling capabilities for temporal features. To address these issues, this paper proposes an intelligent prediction architecture for CT tubes’ remaining useful life based on a dual-branch neural network. This architecture consists of two specialized branches: a residual self-attention BiLSTM (RSA-BiLSTM) and a multi-layer dilation temporal convolutional network (D-TCN). The RSA-BiLSTM branch extracts multi-scale features and also enhances the long-term dependency modeling capability for temporal data. The D-TCN branch captures multi-scale temporal features through multi-layer dilated convolutions, effectively handling non-linear changes in the degradation phase. Furthermore, a dynamic phase detector is applied to integrate the prediction results from both branches. In terms of optimization strategy, a dynamically weighted triplet mixed loss function is designed to adjust the weight ratios of different prediction tasks, effectively solving the problems of sample imbalance and uneven prediction accuracy. Experimental results using leave-one-out cross-validation (LOOCV) on six different CT tube datasets show that the proposed method achieved significant advantages over five comparison models, with an average MSE of 2.92, MAE of 0.46, and R2 of 0.77. The LOOCV strategy ensures robust evaluation by testing each tube dataset independently while training on the remaining five, providing reliable generalization assessment across different CT equipment. Ablation experiments further confirmed that the collaborative design of multiple components is significant for improving the accuracy of X-ray tubes remaining life prediction.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Engineering, West China Hospital, Sichuan University, Chengdu 610041, China.
- Innovation Institute for Integration of Medicine and Engineering, West China Hospital, Sichuan University, Chengdu 610041, China.
- Chengdu Women's and Children's Central Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu 611731, China.
Förderung
- National Key R&D Program of China
- National Key R&D Program of China
Zitieren
APA
Chen, Z., Liu, Y., Qin, Z., Li, H., Xie, S., Fan, L., Liu, Q., & Huang, J. (2025). Dual-Branch Deep Learning with Dynamic Stage Detection for CT Tube Life Prediction. Sensors, 25(15), 4790. https://doi.org/10.3390/s25154790
Vancouver
Chen Z, Liu Y, Qin Z, Li H, Xie S, Fan L, et al. Dual-Branch Deep Learning with Dynamic Stage Detection for CT Tube Life Prediction. Sensors. 2025;25(15):4790. doi:10.3390/s25154790
BibTeX
@article{Chen2025,
author = {Chen, Zhu and Liu, Yuedan and Qin, Zhibin and Li, Haojie and Xie, Siyuan and Fan, Litian and Liu, Qilin and Huang, Jin},
title = {Dual-Branch Deep Learning with Dynamic Stage Detection for CT Tube Life Prediction},
journal = {Sensors},
year = {2025},
volume = {25},
number = {15},
pages = {4790},
doi = {10.3390/s25154790}
}