Precise and Continuous Biomass Measurement for Plant Growth Using a Low-Cost Sensor Setup
Sensors · 02.08.2025 · 25 (15) · 4770
DOI: 10.3390/s25154770 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 02.08.2025. Verfasst von Lukas Munser und 5 weiteren Autor:innen. Beteiligte Einrichtung: Professorship Automatic Control and System Dynamics, Technische Universität Chemnitz, Reichenhainer Straße 70, 09126 Chemnitz, Germany. Hauptthemen laut MEDLINE: Biomass, Plant Development, Biosensing Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Saxon State Ministry for Science and the Arts, Sächsisches Staatsministerium für Wissenschaft, Kultur und Tourismus, Saxon State Parliament.
Abstract (Originalsprache)
Continuous and accurate biomass measurement is a critical enabler for control, decision making, and optimization in modern plant production systems. It supports the development of plant growth models for advanced control strategies like model predictive control, and enables responsive, data-driven, and plant state-dependent cultivation. Traditional biomass measurement methods, such as destructive sampling, are time-consuming and unsuitable for high-frequency monitoring. In contrast, image-based estimation using computer vision and deep learning requires frequent retraining and is sensitive to changes in lighting or plant morphology. This work introduces a low-cost, load-cell-based biomass monitoring system tailored for vertical farming applications. The system operates at the level of individual growing trays, offering a valuable middle ground between impractical plant-level sensing and overly coarse rack-level measurements. Tray-level data allow localized control actions, such as adjusting light spectrum and intensity per tray, thereby enhancing the utility of controllable LED systems. This granularity supports layer-specific optimization and anomaly detection, which are not feasible with rack-level feedback. The biomass sensor is easily scalable and can be retrofitted, addressing common challenges such as mechanical noise and thermal drift. It offers a practical and robust solution for biomass monitoring in dynamic, growing environments, enabling finer control and smarter decision making in both commercial and research-oriented vertical farming systems. The developed sensor was tested and validated against manual harvest data, demonstrating high agreement with actual plant biomass and confirming its suitability for integration into vertical farming systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Professorship Automatic Control and System Dynamics, Technische Universität Chemnitz, Reichenhainer Straße 70, 09126 Chemnitz, Germany.
- Department of Bioresources, Fraunhofer Institute for Molecular Biology and Applied Ecology, Ohlebergsweg 12, 35392 Gießen, Germany.
ORCID-Profile: Lukas Munser, Kiran Kumar Sathyanarayanan, Jonathan Raecke, Mohamed Mokhtar Mansour, Morgan Emily Uland, Stefan Streif
Förderung
- Saxon State Ministry for Science and the Arts
- Sächsisches Staatsministerium für Wissenschaft, Kultur und Tourismus
- Saxon State Parliament
Zitieren
APA
Munser, L., Sathyanarayanan, K. K., Raecke, J., Mansour, M. M., Uland, M. E., & Streif, S. (2025). Precise and Continuous Biomass Measurement for Plant Growth Using a Low-Cost Sensor Setup. Sensors, 25(15), 4770. https://doi.org/10.3390/s25154770
Vancouver
Munser L, Sathyanarayanan KK, Raecke J, Mansour MM, Uland ME, Streif S. Precise and Continuous Biomass Measurement for Plant Growth Using a Low-Cost Sensor Setup. Sensors. 2025;25(15):4770. doi:10.3390/s25154770
BibTeX
@article{Munser2025,
author = {Munser, Lukas and Sathyanarayanan, Kiran Kumar and Raecke, Jonathan and Mansour, Mohamed Mokhtar and Uland, Morgan Emily and Streif, Stefan},
title = {Precise and Continuous Biomass Measurement for Plant Growth Using a Low-Cost Sensor Setup},
journal = {Sensors},
year = {2025},
volume = {25},
number = {15},
pages = {4770},
doi = {10.3390/s25154770}
}
EUVIMED