EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Joint LiDAR and Camera Calibration Algorithm Based on an Original 3D Calibration Plate

Ziyang Cui, Yi Wang iD, Xiaodong Chen, Huaiyu Cai

Sensors · 23.07.2025 · 25 (15) · 4558

DOI: 10.3390/s25154558 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 23.07.2025. Verfasst von Ziyang Cui und 3 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Opto-Electronics Information Technology of Ministry of Education, College of Precision Instrument and Opto-Electronics Engineering,…. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An accurate extrinsic calibration between LiDAR and cameras is essential for effective sensor fusion, directly impacting the perception capabilities of autonomous driving systems. Although prior calibration approaches using planar and point features have yielded some success, they suffer from inherent limitations. Specifically, methods that rely on fitting planar contours using depth-discontinuous points are prone to systematic errors, which hinder the precise extraction of the 3D positions of feature points. This, in turn, compromises the accuracy and robustness of the calibration. To overcome these challenges, this paper introduces a novel 3D calibration plate incorporating the gradient depth, localization markers, and corner features. At the point cloud level, the gradient depth enables the accurate estimation of the 3D coordinates of feature points. At the image level, corner features and localization markers facilitate the rapid and precise acquisition of 2D pixel coordinates, with minimal interference from environmental noise. This method establishes a rigorous and systematic framework to enhance the accuracy of LiDAR–camera extrinsic calibrations. In a simulated environment, experimental results demonstrate that the proposed algorithm achieves a rotation error below 0.002 radians and a translation error below 0.005 m.

Schlagwörter

Stichwörter der Autor:innen

calibrationcamera and LiDARfeature pointintelligent vehicle

Autor:innen und Institutionen

  • Key Laboratory of Opto-Electronics Information Technology of Ministry of Education, College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.

ORCID-Profile: Yi Wang

Zitieren

APA

Cui, Z., Wang, Y., Chen, X., & Cai, H. (2025). A Joint LiDAR and Camera Calibration Algorithm Based on an Original 3D Calibration Plate. Sensors, 25(15), 4558. https://doi.org/10.3390/s25154558

Vancouver

Cui Z, Wang Y, Chen X, Cai H. A Joint LiDAR and Camera Calibration Algorithm Based on an Original 3D Calibration Plate. Sensors. 2025;25(15):4558. doi:10.3390/s25154558

BibTeX
@article{Cui2025,
  author = {Cui, Ziyang and Wang, Yi and Chen, Xiaodong and Cai, Huaiyu},
  title = {A Joint LiDAR and Camera Calibration Algorithm Based on an Original 3D Calibration Plate},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {15},
  pages = {4558},
  doi = {10.3390/s25154558}
}
Kostenlos starten →