EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Wind Turbine Fault Detection Through Autoencoder-Based Neural Network and FMSA

Welker Facchini Nogueira iD, Arthur Henrique de Andrade Melani iD, Gilberto Francisco Martha de Souza iD

Sensors · 19.07.2025 · 25 (14) · 4499

DOI: 10.3390/s25144499 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 19.07.2025. Verfasst von Welker Facchini Nogueira und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechatronics and Mechanical Systems Engineering, Polytechnic School, University of Sao Paulo, Sao Paulo 05508-010, SP, Brazil. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Council for Scientific and Technological Development, Fundação de Amparo à Pesquisa do Estado de São Paulo, Brazilian National Council for Scientific and Technological Development/Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Amid the global shift toward clean energy, wind power has emerged as a critical pillar of the modern energy matrix. To improve the reliability and maintainability of wind farms, this work proposes a novel hybrid fault detection approach that combines expert-driven diagnostic knowledge with data-driven modeling. The framework integrates autoencoder-based neural networks with Failure Mode and Symptoms Analysis, leveraging the strengths of both methodologies to enhance anomaly detection, feature selection, and fault localization. The methodology comprises five main stages: (i) the identification of failure modes and their observable symptoms using FMSA, (ii) the acquisition and preprocessing of SCADA monitoring data, (iii) the development of dedicated autoencoder models trained exclusively on healthy operational data, (iv) the implementation of an anomaly detection strategy based on the reconstruction error and a persistence-based rule to reduce false positives, and (v) evaluation using performance metrics. The approach adopts a fault-specific modeling strategy, in which each turbine and failure mode is associated with a customized autoencoder. The methodology was first validated using OpenFAST 3.5 simulated data with induced faults comprising normal conditions and a 1% mass imbalance fault on a blade, enabling the verification of its effectiveness under controlled conditions. Subsequently, the methodology was applied to a real-world SCADA data case study from wind turbines operated by EDP, employing historical operational data from turbines, including thermal measurements and operational variables such as wind speed and generated power. The proposed system achieved 99% classification accuracy on simulated data detect anomalies up to 60 days before reported failures in real operational conditions, successfully identifying degradations in components such as the transformer, gearbox, generator, and hydraulic group. The integration of FMSA improves feature selection and fault localization, enhancing both the interpretability and precision of the detection system. This hybrid approach demonstrates the potential to support predictive maintenance in complex industrial environments.

Schlagwörter

Stichwörter der Autor:innen

FMSAautoencodersfault detectionpredictive maintenancewind turbine

Autor:innen und Institutionen

  • Department of Mechatronics and Mechanical Systems Engineering, Polytechnic School, University of Sao Paulo, Sao Paulo 05508-010, SP, Brazil.

ORCID-Profile: Welker Facchini Nogueira, Arthur Henrique de Andrade Melani, Gilberto Francisco Martha de Souza

Förderung

  • National Council for Scientific and Technological Development
  • Fundação de Amparo à Pesquisa do Estado de São Paulo
  • Brazilian National Council for Scientific and Technological Development/Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
  • University of São Paulo (USP)
  • FAPESP–São Paulo Research Foundation

Zitieren

APA

Nogueira, W. F., Melani, A. H. A., & de Souza, G. F. M. (2025). Wind Turbine Fault Detection Through Autoencoder-Based Neural Network and FMSA. Sensors, 25(14), 4499. https://doi.org/10.3390/s25144499

Vancouver

Nogueira WF, Melani AHA, de Souza GFM. Wind Turbine Fault Detection Through Autoencoder-Based Neural Network and FMSA. Sensors. 2025;25(14):4499. doi:10.3390/s25144499

BibTeX
@article{Nogueira2025,
  author = {Nogueira, Welker Facchini and Melani, Arthur Henrique de Andrade and de Souza, Gilberto Francisco Martha},
  title = {Wind Turbine Fault Detection Through Autoencoder-Based Neural Network and FMSA},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {14},
  pages = {4499},
  doi = {10.3390/s25144499}
}
Kostenlos starten →