Agreement Between a Pre-Markered T-Shirt and Manual Marker Placement for Opto-Electronic Plethysmography (OEP) Measures

Nayani G Adhikari iD, Eugénie Hunsicker, Matthew T G Pain iD, John W Dickinson iD, Samantha L Winter iD

Sensors · 2025

DOI: 10.3390/s25144464 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Nayani G Adhikari und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough LE11 3TU, UK. Hauptthemen laut MEDLINE: Plethysmography, Clothing. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Opto-electronic plethysmography (OEP) is used to measure chest wall compartment volumes and their synchronisation. Breathing pattern disorder (BPD) can be distinguished using the phase angles between these chest wall compartments during exercise. However, the time taken to manually place the standard OEP model involving 89 reflective markers is high during clinical application. The purpose of this study was to investigate the use of a pre-markered T-shirt instead of markers applied directly to the skin at rest, during different exercise intensities and recovery. Thirty-nine healthy participants (24 male, 15 female) aged 18–40 years performed an incremental cycling test with the skin-mounted OEP marker set. Participants then repeated the same cycling test with a pre-markered T-shirt. Across all test conditions, the T-shirt showed a strong level of agreement (Intraclass correlation coefficient (ICC) ≥ 0.9) with the standard breath-by-breath (BbB) gas analyser. Moreover, ICC values exceeded 0.8 for compartment contributions across all test conditions, indicating excellent agreement with the skin-mounted markers. The phase angles between compartments showed the best agreement during the moderate exercise level (0.6 < ICC < 0.8). In conclusion, the pre-markered T-shirt presents a viable solution for the quick monitoring of breathing patterns, as well as an effective tool in diagnosing BPD during exercise.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PlethysmographyClothingHumansMaleFemaleAdultAdolescentYoung AdultExerciseRespirationThoracic WallExercise Test

Stichwörter der Autor:innen

breathing pattern disordermotion capture techniqueopto-electronic plethysmographyphase angletidal volume

Autor:innen und Institutionen

  • School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough LE11 3TU, UK.
  • Population Health Research Institute, City St George's, University of London, London SW17 0RE, UK.
  • Department of Mathematical Sciences, Loughborough University, Loughborough LE11 3TU, UK.
  • School of Sport and Exercise Sciences, University of Kent, Canterbury CT2 7NZ, UK.

ORCID-Profile: Nayani G Adhikari, Matthew T G Pain, John W Dickinson, Samantha L Winter

Zitieren

APA

Adhikari, N. G., Hunsicker, E., Pain, M. T. G., Dickinson, J. W., & Winter, S. L. (2025). Agreement Between a Pre-Markered T-Shirt and Manual Marker Placement for Opto-Electronic Plethysmography (OEP) Measures. Sensors. https://doi.org/10.3390/s25144464

Vancouver

Adhikari NG, Hunsicker E, Pain MTG, Dickinson JW, Winter SL. Agreement Between a Pre-Markered T-Shirt and Manual Marker Placement for Opto-Electronic Plethysmography (OEP) Measures. Sensors. 2025. doi:10.3390/s25144464

BibTeX
@article{Adhikari2025,
  author = {Adhikari, Nayani G and Hunsicker, Eugénie and Pain, Matthew T G and Dickinson, John W and Winter, Samantha L},
  title = {Agreement Between a Pre-Markered T-Shirt and Manual Marker Placement for Opto-Electronic Plethysmography (OEP) Measures},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25144464}
}