Improving Cell Detection and Tracking in Microscopy Images Using YOLO and an Enhanced DeepSORT Algorithm
Sensors · 12.07.2025 · 25 (14) · 4361
DOI: 10.3390/s25144361 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 12.07.2025. Verfasst von Mokhaled N A Al-Hamadani und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Data Science and Visualization, Faculty of Informatics, University of Debrecen, 4032 Debrecen, Hungary. Hauptthemen laut MEDLINE: Algorithms, Microscopy, Image Processing, Computer-Assisted, Cell Tracking. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: TKP2021-NKTA, National Research, Development, and Innovation Fund of Hungary.
Abstract (Originalsprache)
Accurate and automated detection and tracking of cells in microscopy images is a persistent challenge in biotechnology and biomedical research. Effective detection and tracking are crucial for understanding biological processes and extracting meaningful data for subsequent simulations. In this study, we present an integrated pipeline that leverages a fine-tuned YOLOv8x model for detecting cells and cell divisions across microscopy image series. While YOLOv8x exhibits strong detection capabilities, it occasionally misses certain cells, leading to gaps in data. To mitigate this, we incorporate the DeepSORT tracking algorithm, which enhances data association and reduces the cells’ identity (ID) switches by utilizing a pre-trained convolutional network for robust multi-object tracking. This combination ensures continuous detection and compensates for missed detections, thereby improving overall recall. Our approach achieves a recall of 93.21% with the enhanced DeepSORT algorithm, compared to the 53.47% recall obtained by the original YOLOv8x model. The proposed pipeline effectively extracts detailed information from structured image datasets, providing a reliable approximation of cellular processes in culture environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Data Science and Visualization, Faculty of Informatics, University of Debrecen, 4032 Debrecen, Hungary.
- Doctoral School of Informatics, University of Debrecen, 4032 Debrecen, Hungary.
- Department of Network and Computer Software Technologies, Hawija Technical Institute, Northern Technical University, Kirkuk 36001, Iraq.
- Department of Microbial Biotechnology and Cell Biology, University of Debrecen, Life Sciences Building 1.102, 1 Egyetem Square, 4010 Debrecen, Hungary.
- Department of Information Technologies, University of Limassol, 3-5 Chaidariou Street, Limassol 3020, Cyprus.
- Department of Innovation Technologies, University of Limassol, 3-5 Chaidariou Street, Limassol 3020, Cyprus.
ORCID-Profile: Mokhaled N A Al-Hamadani, Andras Hajdu, Stathis Hadjidemetriou, Luca Ferrarini, Balazs Harangi
Förderung
- TKP2021-NKTA
- National Research, Development, and Innovation Fund of Hungary
Zitieren
APA
Al-Hamadani, M. N. A., Poroszlay, R., Szeman-Nagy, G., Hajdu, A., Hadjidemetriou, S., Ferrarini, L., & Harangi, B. (2025). Improving Cell Detection and Tracking in Microscopy Images Using YOLO and an Enhanced DeepSORT Algorithm. Sensors, 25(14), 4361. https://doi.org/10.3390/s25144361
Vancouver
Al-Hamadani MNA, Poroszlay R, Szeman-Nagy G, Hajdu A, Hadjidemetriou S, Ferrarini L, et al. Improving Cell Detection and Tracking in Microscopy Images Using YOLO and an Enhanced DeepSORT Algorithm. Sensors. 2025;25(14):4361. doi:10.3390/s25144361
BibTeX
@article{AlHamadani2025,
author = {Al-Hamadani, Mokhaled N A and Poroszlay, Richard and Szeman-Nagy, Gabor and Hajdu, Andras and Hadjidemetriou, Stathis and Ferrarini, Luca and Harangi, Balazs},
title = {Improving Cell Detection and Tracking in Microscopy Images Using YOLO and an Enhanced DeepSORT Algorithm},
journal = {Sensors},
year = {2025},
volume = {25},
number = {14},
pages = {4361},
doi = {10.3390/s25144361}
}
EUVIMED