Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Tomas Pokorny und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Praha, Czech Republic. Hauptthemen laut MEDLINE: Stroke, Microwaves, Brain, Microwave Imaging. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Czech Technical University in Prague, Grant Agency of the Czech Technical University in Prague.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microwave imaging systems show potential as replacements for commonly used stroke diagnostic systems. We developed and tested a 10-port microwave system on a liquid head phantom with ischemic and hemorrhagic strokes of varying sizes and positions. This system allows for visualization of changes in dielectric parameters using the TSVD Born approximation, enabling recognition of stroke position and size from the resulting images. The SVM algorithm effectively distinguishes between ischemic and hemorrhagic strokes, achieving 98% accuracy on experimental data, with 99% accuracy in ischemic scenarios and 97% in hemorrhagic scenarios. Using the TSVD Born algorithm, it was possible to precisely image changes in the absolute permittivity of different stroke locations; however, changes in stroke size were more apparent in the variations of absolute permittivity than in the reconstructed stroke size within the antenna plane. Outside this plane, changes in the S-parameters decreased depending on the distance and size of the stroke, making detection and classification more difficult. One ring of antennas around the head proved insufficient, prompting us to focus on developing a system with antennas positioned around the entire head.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StrokeMicrowavesBrainMicrowave ImagingHumansPhantoms, ImagingAlgorithms

Stichwörter der Autor:innen

SVMTSVD Born approximationbrain strokemicrowave devices

Autor:innen und Institutionen

  • Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Praha, Czech Republic.

ORCID-Profile: Tomas Pokorny, Jan Redr, Hana Laierova, Barbora Smahelova, Jakub Kollar

Förderung

  • Czech Technical University in Prague
  • Grant Agency of the Czech Technical University in Prague

Zitieren

APA

Pokorny, T., Redr, J., Laierova, H., Smahelova, B., & Kollar, J. (2025). An Experimental 10-Port Microwave System for Brain Stroke Diagnosis—Potentials and Limitations. Sensors. https://doi.org/10.3390/s25144360

Vancouver

Pokorny T, Redr J, Laierova H, Smahelova B, Kollar J. An Experimental 10-Port Microwave System for Brain Stroke Diagnosis—Potentials and Limitations. Sensors. 2025. doi:10.3390/s25144360

BibTeX
@article{Pokorny2025,
  author = {Pokorny, Tomas and Redr, Jan and Laierova, Hana and Smahelova, Barbora and Kollar, Jakub},
  title = {An Experimental 10-Port Microwave System for Brain Stroke Diagnosis—Potentials and Limitations},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25144360}
}