EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Visualizing Relaxation in Wearables: Multi-Domain Feature Fusion of HRV Using Fuzzy Recurrence Plots

Puneet Arya iD, Mandeep Singh iD, Mandeep Singh iD

Sensors · 2025

DOI: 10.3390/s25134210 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Puneet Arya und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Instrumentation Engineering, Thapar Institute of Engineering and Technology, Patiala 147004, India. Hauptthemen laut MEDLINE: Heart Rate, Wearable Electronic Devices, Relaxation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Thapar Institute of Engineering and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Traditional relaxation techniques such as meditation and slow breathing often rely on subjective self-assessment, making it difficult to objectively monitor physiological changes. Electrocardiograms (ECG), which are commonly used by clinicians, provide one-dimensional signals to interpret cardiovascular activity. In this study, we introduce a visual interpretation framework that transforms heart rate variability (HRV) time series into fuzzy recurrence plots (FRPs). Unlike ECGs’ linear traces, FRPs are two-dimensional images that reveal distinctive textural patterns corresponding to autonomic changes. These visually rich patterns make it easier for even non-experts with minimal training to track changes in relaxation states. To enable automated detection, we propose a multi-domain feature fusion framework suitable for wearable systems. HRV data were collected from 60 participants during spontaneous and slow-paced breathing sessions. Features were extracted from five domains: time, frequency, non-linear, geometric, and image-based. Feature selection was performed using the Fisher discriminant ratio, correlation filtering, and greedy search. Among six evaluated classifiers, support vector machine (SVM) achieved the highest performance, with 96.6% accuracy and 100% specificity using only three selected features. Our approach offers both human-interpretable visual feedback through FRP and accurate automated detection, making it highly promising for objectively monitoring real-time stress and developing biofeedback systems in wearable devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart RateWearable Electronic DevicesRelaxationHumansElectrocardiographyFuzzy LogicMaleSupport Vector MachineFemaleAdultSignal Processing, Computer-AssistedAlgorithms

Stichwörter der Autor:innen

autonomic nervous systemfuzzy recurrence plotheart-rate variabilityrelaxationslow-paced breathing

Autor:innen und Institutionen

  • Department of Electrical and Instrumentation Engineering, Thapar Institute of Engineering and Technology, Patiala 147004, India.

ORCID-Profile: Puneet Arya, Mandeep Singh, Mandeep Singh

Förderung

  • Thapar Institute of Engineering and Technology

Zitieren

APA

Arya, P., Singh, M., & Singh, M. (2025). Visualizing Relaxation in Wearables: Multi-Domain Feature Fusion of HRV Using Fuzzy Recurrence Plots. Sensors. https://doi.org/10.3390/s25134210

Vancouver

Arya P, Singh M, Singh M. Visualizing Relaxation in Wearables: Multi-Domain Feature Fusion of HRV Using Fuzzy Recurrence Plots. Sensors. 2025. doi:10.3390/s25134210

BibTeX
@article{Arya2025,
  author = {Arya, Puneet and Singh, Mandeep and Singh, Mandeep},
  title = {Visualizing Relaxation in Wearables: Multi-Domain Feature Fusion of HRV Using Fuzzy Recurrence Plots},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25134210}
}
Kostenlos starten →