A Novel Approach to Non-Invasive Intracranial Pressure Wave Monitoring: A Pilot Healthy Brain Study
Sensors · 2025
DOI: 10.3390/s25134042 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Andrius Karaliunas und 11 weiteren Autor:innen. Beteiligte Einrichtung: Health Telematics Science Institute, Kaunas University of Technology, LT-51423 Kaunas, Lithuania. Hauptthemen laut MEDLINE: Intracranial Pressure, Brain, Pulse Wave Analysis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Lietuvos Mokslo Taryba, Research Council of Lithuania.
Abstract (Originalsprache)
Intracranial pressure (ICP) pulse wave morphology, including the ratios of the three characteristic peaks (P1, P2, and P3), offers valuable insights into intracranial dynamics and brain compliance. Traditional invasive methods for ICP pulse wave monitoring pose significant risks, highlighting the need for non-invasive alternatives. This pilot study investigates a novel non-invasive method for monitoring ICP pulse waves through closed eyelids, using a specially designed, liquid-filled, fully passive sensor system named ‘Archimedes 02’. To our knowledge, this is the first technological approach that enables the non-invasive monitoring of ICP pulse waveforms via closed eyelids. This study involved 10 healthy volunteers, aged 26–39 years, who underwent resting-state non-invasive ICP pulse wave monitoring sessions using the ‘Archimedes 02’ device while in the supine position. The recorded signals were processed to extract pulse waves and evaluate their morphological characteristics. The results indicated successful detection of pressure pulse waves, showing the expected three peaks (P1, P2, and P3) in all subjects. The calculated P2/P1 ratios were 0.762 (SD = ±0.229) for the left eye and 0.808 (SD = ±0.310) for the right eye, suggesting normal intracranial compliance across the cohort, despite variations observed in some individuals. Physiological tests—the Valsalva maneuver and the Queckenstedt test, both performed in the supine position—induced statistically significant increases in the P2/P1 and P3/P1 ratios, supporting the notion that non-invasively recorded pressure pulse waves, measured through closed eyelids, reflect intracranial volume and pressure dynamics. Additionally, a transient hypoemic/hyperemic response test performed in the upright position induced signal changes in pressure recordings from the ‘Archimedes 02’ sensor that were consistent with intact cerebral blood flow autoregulation, aligning with established physiological principles. These findings indicate that ICP pulse waves and their dynamic changes can be monitored non-invasively through closed eyelids, offering a potential method for brain monitoring in patients for whom invasive procedures are not feasible.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Health Telematics Science Institute, Kaunas University of Technology, LT-51423 Kaunas, Lithuania.
- Laboratory of Heat-Equipment Research and Testing, Lithuanian Energy Institute, LT-44403 Kaunas, Lithuania.
- Visual Communication Design, Faculty of Art, Design and Architecture, Isik University, TR-34980 Istanbul, Türkiye.
- Eye Clinic, Lithuanian University of Health Sciences, LT-50161 Kaunas, Lithuania.
ORCID-Profile: Vytautas Petkus, Ingrida Januleviciene
Förderung
- Lietuvos Mokslo Taryba
- Research Council of Lithuania
Zitieren
APA
Karaliunas, A., Bartusis, L., Krakauskaite, S., Chaleckas, E., Deimantavicius, M., Hamarat, Y., Petkus, V., Stulge, T., Ratkunas, V., Celikkaya, G., Januleviciene, I., & Ragauskas, A. (2025). A Novel Approach to Non-Invasive Intracranial Pressure Wave Monitoring: A Pilot Healthy Brain Study. Sensors. https://doi.org/10.3390/s25134042
Vancouver
Karaliunas A, Bartusis L, Krakauskaite S, Chaleckas E, Deimantavicius M, Hamarat Y, et al. A Novel Approach to Non-Invasive Intracranial Pressure Wave Monitoring: A Pilot Healthy Brain Study. Sensors. 2025. doi:10.3390/s25134042
BibTeX
@article{Karaliunas2025,
author = {Karaliunas, Andrius and Bartusis, Laimonas and Krakauskaite, Solventa and Chaleckas, Edvinas and Deimantavicius, Mantas and Hamarat, Yasin and Petkus, Vytautas and Stulge, Toma and Ratkunas, Vytenis and Celikkaya, Guven and Januleviciene, Ingrida and Ragauskas, Arminas},
title = {A Novel Approach to Non-Invasive Intracranial Pressure Wave Monitoring: A Pilot Healthy Brain Study},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25134042}
}
EUVIMED