EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

On-Site and Sensitive Pipeline Oxygen Detection Equipment Based on TDLAS

Yanfei Zhang iD, Kaiping Yuan, Zhaoan Yu, Yunhan Zhang, Xin Liu, Tieliang Lv iD

Sensors · 27.06.2025 · 25 (13) · 4027

DOI: 10.3390/s25134027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 27.06.2025. Verfasst von Yanfei Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Integrated Chips and Systems, College of Integrated Circuits and Micro-Nano Electronics, Fudan University, Shanghai 200433, C…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The application of oxygen sensors based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) in the industrial field has received extensive attention. However, most of the existing studies construct detection systems using discrete devices, making it difficult to apply them in the industrial field. In this work, through the optimization of the sensor circuit, the size of the core components of the sensor is reduced to 7.8 × 7.8 × 11.8 cm3, integrating the laser, photodetector, and system control circuit. A novel integrated optical path design is proposed for the optical mechanical structure, which enhances the structural integration and long-term optical path stability while reducing the system assembly complexity. The interlocking design of the laser-driven digital-to-analog converter (DAC) and photocurrent acquisition analog-to-digital converter (ADC) reduces the requirements of the harmonic signal extraction for the system hardware. By adopting a high-precision ADC and a high-resolution pulse-width modulation (PWM), the peak-to-peak value of the laser temperature control noise is reduced to 2 m°C, thereby reducing the detection noise of the sensor. This oxygen detection system has a minimum response time of 0.1 s. Under the condition of a 0.5 m detection optical path, the Allan variance shows that when the integration time is 5.6 s, the detection limit reaches 53.4 ppm, which is ahead of the detection accuracy of similar equipment under the very small system size.

Schlagwörter

Stichwörter der Autor:innen

oxygen detectiontunable diode laser absorption spectroscopy

Autor:innen und Institutionen

  • State Key Laboratory of Integrated Chips and Systems, College of Integrated Circuits and Micro-Nano Electronics, Fudan University, Shanghai 200433, China.
  • Frontier Institute of Chip and System Technology, Fudan University, Shanghai 200433, China.
  • Institute of Microelectronics, Chinese Academy of Sciences, Beijing 100029, China.
  • School of microelectronics, Fudan University, Shanghai 200433, China.

ORCID-Profile: Yanfei Zhang, Tieliang Lv

Zitieren

APA

Zhang, Y., Yuan, K., Yu, Z., Zhang, Y., Liu, X., & Lv, T. (2025). On-Site and Sensitive Pipeline Oxygen Detection Equipment Based on TDLAS. Sensors, 25(13), 4027. https://doi.org/10.3390/s25134027

Vancouver

Zhang Y, Yuan K, Yu Z, Zhang Y, Liu X, Lv T. On-Site and Sensitive Pipeline Oxygen Detection Equipment Based on TDLAS. Sensors. 2025;25(13):4027. doi:10.3390/s25134027

BibTeX
@article{Zhang2025,
  author = {Zhang, Yanfei and Yuan, Kaiping and Yu, Zhaoan and Zhang, Yunhan and Liu, Xin and Lv, Tieliang},
  title = {On-Site and Sensitive Pipeline Oxygen Detection Equipment Based on TDLAS},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {13},
  pages = {4027},
  doi = {10.3390/s25134027}
}
Kostenlos starten →