EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Simulation Design of an Elliptical Loop-Microstrip Array for Brain Lobe Imaging with an 11.74 Tesla MRI System

Daniel Hernandez iD, Taewoo Nam iD, Eunwoo Lee, Yeji Han, Yeunchul Ryu iD, Jun-Young Chung iD, Kyoung-Nam Kim iD

Sensors · 2025

DOI: 10.3390/s25134021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Daniel Hernandez und 6 weiteren Autor:innen. Beteiligte Einrichtung: Neuroscience Research Institute, Gachon University, Incheon 21988, Republic of Korea. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and ICT, Korean government (MSIT).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetic resonance imaging (MRI) is a powerful medical imaging technique used for acquiring high-resolution anatomical and functional images of the human body. With the development of an 11.74 Tesla (T) human MRI system at our facility, we are designing novel radiofrequency (RF) coils optimized for brain imaging at ultra-high fields. To meet specific absorption rate (SAR) safety limits, this study focuses on localized imaging of individual brain lobes rather than whole-brain array designs. Conventional loop coils, while widely used, offer limited |B1|-field uniformity at 500 MHz—the Larmor frequency at 11.74 T, which can reduce image quality. Therefore, it is important to develop antennas and coils for highly uniform fields. As an alternative, we propose an elliptical microstrip design, which combines the compact resonant properties of microstrips with the enhanced field coverage provided by loop geometry. We simulated a three-element elliptical microstrip array and compared its performance with a conventional loop coil. The proposed design demonstrated improved magnetic field uniformity and coverage across targeted brain regions. Preliminary bench-top validation confirmed the feasibility of resonance tuning at 500 MHz, supporting its potential for future high-field MRI applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainHumansEquipment DesignComputer SimulationPhantoms, Imaging

Stichwörter der Autor:innen

MRIelectromagnetic simulationsmagnetic fieldsmicrostrip

Autor:innen und Institutionen

  • Neuroscience Research Institute, Gachon University, Incheon 21988, Republic of Korea.
  • Department of Health Sciences and Technology, GAIHST, Gachon University, Incheon 21999, Republic of Korea.
  • Department of Biomedical Engineering, Gachon University, Seongnam 13120, Republic of Korea.
  • Department of Radiological Science, Gachon University, Incheon 21999, Republic of Korea.
  • Department of Neuroscience, College of Medicine, Gachon University, Incheon 21565, Republic of Korea.

ORCID-Profile: Daniel Hernandez, Taewoo Nam, Yeunchul Ryu, Jun-Young Chung, Kyoung-Nam Kim

Förderung

  • Ministry of Science and ICT
  • Korean government (MSIT)

Zitieren

APA

Hernandez, D., Nam, T., Lee, E., Han, Y., Ryu, Y., Chung, J. Y., & Kim, K. N. (2025). Simulation Design of an Elliptical Loop-Microstrip Array for Brain Lobe Imaging with an 11.74 Tesla MRI System. Sensors. https://doi.org/10.3390/s25134021

Vancouver

Hernandez D, Nam T, Lee E, Han Y, Ryu Y, Chung JY, et al. Simulation Design of an Elliptical Loop-Microstrip Array for Brain Lobe Imaging with an 11.74 Tesla MRI System. Sensors. 2025. doi:10.3390/s25134021

BibTeX
@article{Hernandez2025,
  author = {Hernandez, Daniel and Nam, Taewoo and Lee, Eunwoo and Han, Yeji and Ryu, Yeunchul and Chung, Jun-Young and Kim, Kyoung-Nam},
  title = {Simulation Design of an Elliptical Loop-Microstrip Array for Brain Lobe Imaging with an 11.74 Tesla MRI System},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25134021}
}
Kostenlos starten →