Consistency Is Key: A Secondary Analysis of Wearable Motion Sensor Accuracy Measuring Knee Angles Across Activities of Daily Living Before and After Knee Arthroplasty
Sensors · 25.06.2025 · 25 (13) · 3942
DOI: 10.3390/s25133942 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 25.06.2025. Verfasst von Robert C Marchand und 6 weiteren Autor:innen. Beteiligte Einrichtung: Ortho Rhode Island, Wakefield, RI 02879, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Wearable Electronic Devices, Activities of Daily Living, Knee Joint. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Stryker Orthopaedics.
Abstract (Originalsprache)
Background
Monitoring knee range of motion (ROM) after total knee arthroplasty (TKA) via clinically deployed wearable motion sensors is increasingly common. Prior work from our own lab showed promising results in one wearable motion sensor system; however, we did not investigate errors across different activities. Accordingly, herein we conducted secondary analyses of error using wearable inertial measurement units (IMUs) quantifying sagittal knee angles across activities in TKA patients.
Methods
After Institutional Review Board (IRB) approval, TKA patients were recruited for participation in two visits (n = 20 enrolled, n = 5 lost to follow-up). Following a sensor tutorial (MotionSense, Stryker, Mahwah, NJ, USA), sensors and motion capture (MOCAP) markers were applied for data capture before surgery. One surgeon then performed TKA. An identical data capture was then completed postoperatively. MOCAP and wearable motion sensor knee angles were computed during a series of activities and compared. Two-way ANOVA evaluated the impact of time (pre- vs. post-TKA) and activity on average error. Another two-way ANOVA was completed, assessing if error at local maxima was different than at local minima and if either was different across activities.
Results
Pre-TKA/post-TKA errors were not different. No differences were noted across activities. On average, the errors were under clinically acceptable thresholds (i.e., 4.9 ± 2.6° vs. ≤5°).
Conclusions
With average error ≤ 5°, these specific sensors accurately quantify knee angles before/after surgical intervention. Future investigations should explore leveraging this type of technology to evaluate preoperative function decline and postoperative function recovery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ortho Rhode Island, Wakefield, RI 02879, USA.
- Department Kinesiology, University of Rhode Island, Kingston, RI 02881, USA.
- Department of Electrical, Computer, and Biomedical Engineering, University of Rhode Island, Kingston, RI 02881, USA.
ORCID-Profile: Shayan Khodabakhsh, Ryan M Chapman
Förderung
- Stryker Orthopaedics
Zitieren
APA
Marchand, R. C., Taylor, K. B., Kaczynski, E. C., Richards, S., Hutchinson, J. B., Khodabakhsh, S., & Chapman, R. M. (2025). Consistency Is Key: A Secondary Analysis of Wearable Motion Sensor Accuracy Measuring Knee Angles Across Activities of Daily Living Before and After Knee Arthroplasty. Sensors, 25(13), 3942. https://doi.org/10.3390/s25133942
Vancouver
Marchand RC, Taylor KB, Kaczynski EC, Richards S, Hutchinson JB, Khodabakhsh S, et al. Consistency Is Key: A Secondary Analysis of Wearable Motion Sensor Accuracy Measuring Knee Angles Across Activities of Daily Living Before and After Knee Arthroplasty. Sensors. 2025;25(13):3942. doi:10.3390/s25133942
BibTeX
@article{Marchand2025,
author = {Marchand, Robert C and Taylor, Kelly B and Kaczynski, Emily C and Richards, Skye and Hutchinson, Jayson B and Khodabakhsh, Shayan and Chapman, Ryan M},
title = {Consistency Is Key: A Secondary Analysis of Wearable Motion Sensor Accuracy Measuring Knee Angles Across Activities of Daily Living Before and After Knee Arthroplasty},
journal = {Sensors},
year = {2025},
volume = {25},
number = {13},
pages = {3942},
doi = {10.3390/s25133942}
}
EUVIMED