EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Numerical Analysis of a SiN Digital Fourier Transform Spectrometer for a Non-Invasive Skin Cancer Biosensor

Miguel Ángel Nava Blanco iD, Gerardo Antonio Castañón Ávila iD

Sensors · 2025

DOI: 10.3390/s25123792 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Miguel Ángel Nava Blanco und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Engineering and Science, Tecnologico de Monterrey, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Mexico. Hauptthemen laut MEDLINE: Biosensing Techniques, Spectrum Analysis, Raman, Skin Neoplasms. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Secretaría de Ciencia, Humanidades, Tecnología e Innovación (SeCiHTI).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Early detection and continuous monitoring of diseases are critical to improving patient outcomes, treatment adherence, and diagnostic accuracy. Traditional melanoma diagnosis relies primarily on visual assessment and biopsy, with reported accuracies ranging from 50% to 90% and significant inter-observer variability. Among emerging diagnostic technologies, Raman spectroscopy has demonstrated considerable promise for non-invasive disease detection, particularly in early-stage skin cancer identification. A portable, real-time Raman spectroscopy system could significantly enhance diagnostic precision, reduce biopsy reliance, and expedite diagnosis. However, miniaturization of Raman spectrometers for portable use faces significant challenges, including weak signal intensity, fluorescence interference, and inherent trade-offs between spectral resolution and the signal-to-noise ratio. Recent advances in silicon photonics present promising solutions by facilitating efficient light collection, enhancing optical fields via high-index-contrast waveguides, and allowing compact integration of photonic components. This work introduces a numerical analysis of an integrated digital Fourier transform spectrometer implemented on a silicon-nitride (SiN) platform, specifically designed for Raman spectroscopy. The proposed system employs a switch-based digital Fourier transform spectrometer architecture coupled with a single optical power meter for detection. Utilizing a regularized regression method, we successfully reconstructed Raman spectra in the 800 cm−1 to 1800 cm−1 range, covering spectra of both benign and malignant skin lesions. Our results demonstrate the capability of the proposed system to effectively differentiate various skin cancer types, highlighting its feasibility as a non-invasive diagnostic sensor.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesSpectrum Analysis, RamanSkin NeoplasmsHumansFourier AnalysisMelanoma

Stichwörter der Autor:innen

Raman spectroscopysilicon integrated photonicsskin cancer

Autor:innen und Institutionen

  • School of Engineering and Science, Tecnologico de Monterrey, Ave. Eugenio Garza Sada 2501, Monterrey 64849, Mexico.

ORCID-Profile: Miguel Ángel Nava Blanco, Gerardo Antonio Castañón Ávila

Förderung

  • Secretaría de Ciencia, Humanidades, Tecnología e Innovación (SeCiHTI)

Zitieren

APA

Nava Blanco, M. Á., & Castañón Ávila, G. A. (2025). Numerical Analysis of a SiN Digital Fourier Transform Spectrometer for a Non-Invasive Skin Cancer Biosensor. Sensors. https://doi.org/10.3390/s25123792

Vancouver

Nava Blanco MÁ, Castañón Ávila GA. Numerical Analysis of a SiN Digital Fourier Transform Spectrometer for a Non-Invasive Skin Cancer Biosensor. Sensors. 2025. doi:10.3390/s25123792

BibTeX
@article{NavaBlanco2025,
  author = {Nava Blanco, Miguel Ángel and Castañón Ávila, Gerardo Antonio},
  title = {Numerical Analysis of a SiN Digital Fourier Transform Spectrometer for a Non-Invasive Skin Cancer Biosensor},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25123792}
}
Kostenlos starten →