Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Takahiro Yamane und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Informatics, Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama 700…. Hauptthemen laut MEDLINE: Machine Learning, Accelerometry, Human Activities. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS, Japan Society for the Promotion of Science (JSPS) KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Human activity recognition using wearable accelerometer data can be a useful digital biomarker for severity assessment and the diagnosis of diseases, where the relationship between onset and patient activity is crucial. For long-term monitoring in clinical settings, the volume of data collected over time should be minimized to reduce power consumption, computational load, and communication volume. This study aimed to determine the lowest sampling frequency that maintains recognition accuracy for each activity. Thirty healthy participants wore nine-axis accelerometer sensors at five body locations and performed nine activities. Machine-learning-based activity recognition was conducted using data sampled at 100, 50, 25, 20, 10, and 1 Hz. Data from the non-dominant wrist and chest, which have previously shown high recognition accuracy, were used. Reducing the sampling frequency to 10 Hz did not significantly affect the recognition accuracy for either location. However, lowering the frequency to 1 Hz decreases the accuracy of many activities, particularly brushing teeth. Using data with a 10 Hz sampling frequency can maintain recognition accuracy while decreasing data volume, enabling long-term patient monitoring and device miniaturization for clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Machine LearningAccelerometryHuman ActivitiesHumansMaleFemaleAdultWearable Electronic DevicesMonitoring, Physiologic

Stichwörter der Autor:innen

digital biomarkersdigital healthhuman activity recognitionmachine learningsampling frequencywearable devices

Autor:innen und Institutionen

  • Department of Biomedical Informatics, Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama 700-8530, Japan.
  • Faculty of Health Sciences, Okayama University Medical School, Okayama 700-8558, Japan.

ORCID-Profile: Takahiro Yamane, Mizuki Morita

Förderung

  • JSPS
  • Japan Society for the Promotion of Science (JSPS) KAKENHI

Zitieren

APA

Yamane, T., Kimura, M., & Morita, M. (2025). Effects of Sampling Frequency on Human Activity Recognition with Machine Learning Aiming at Clinical Applications. Sensors. https://doi.org/10.3390/s25123780

Vancouver

Yamane T, Kimura M, Morita M. Effects of Sampling Frequency on Human Activity Recognition with Machine Learning Aiming at Clinical Applications. Sensors. 2025. doi:10.3390/s25123780

BibTeX
@article{Yamane2025,
  author = {Yamane, Takahiro and Kimura, Moeka and Morita, Mizuki},
  title = {Effects of Sampling Frequency on Human Activity Recognition with Machine Learning Aiming at Clinical Applications},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25123780}
}
Kostenlos starten →