Robust Estimation of Unsteady Beat-to-Beat Systolic Blood Pressure Trends Using Photoplethysmography Contextual Cycles
Sensors · 09.06.2025 · 25 (12) · 3625
DOI: 10.3390/s25123625 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 09.06.2025. Verfasst von Xinyi Huang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Sun Yat-sen University, Shenzhen 518107, China. Hauptthemen laut MEDLINE: Photoplethysmography, Blood Pressure, Blood Pressure Determination. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation, National Key R&D Program of China, Guangzhou Science Technology Planning Project.
Abstract (Originalsprache)
Hypertension and blood pressure variability (BPV) are major risk factors for cardiovascular disease (CVD). Single-channel photoplethysmography (PPG) has emerged as a promising daily blood pressure (BP) monitoring tool. However, estimating BP trends presents challenges due to complex temporal dependencies and continuous fluctuations. Traditional methods often address BP prediction as isolated tasks and focus solely on temporal dependencies within a limited time window, which may fall short of capturing the intricate BP fluctuation patterns implied in varying time spans, particularly amidst constant BP variations. To address this, we propose a novel deep learning model featuring a two-stage architecture and a new input structure called contextual cycles. This model estimates beat-to-beat systolic blood pressure (SBP) trends as a sequence prediction task, transforming the output from a single SBP value into a sequence. In the first stage, parallel ResU Blocks are utilized to extract fine-grained features from each cycle. The generated feature vectors are then processed by Transformer layers with relative position encoding (RPE) to capture inter-cycle interactions and temporal dependencies in the second stage. Our proposed model demonstrates robust performance in beat-to-beat SBP trend estimation, achieving a mean absolute error (MAE) of 3.186 mmHg, a Pearson correlation coefficient applied to sequences (Rseq) of 0.743, and a variability error (VE) of 1.199 mmHg. It excels in steady and abrupt substantial fluctuation states, outperforming baseline models. The results reveal that our method meets the requirements of the AAMI standard and achieves grade A according to the BHS standard. Overall, our proposed method shows significant potential for reliable daily health monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Biomedical Engineering, Sun Yat-sen University, Shenzhen 518107, China.
- Department of Information Technology, Durban University of Technology, Durban 4001, South Africa.
- General Hospital of the Southern Theatre Command, Guangzhou 510010, China.
- The First School of Clinical Medicine, Southern Medical University, Guangzhou 510515, China.
ORCID-Profile: Xianbin Zhang, Richard Millham, Lin Xu, Wanqing Wu
Förderung
- National Research Foundation
- National Key R&D Program of China
- Guangzhou Science Technology Planning Project
- National Clinical Research Center for Geriatrics
- National Key R&D Program of China
- National Research Foundation of South Africa
Zitieren
APA
Huang, X., Zhang, X., Millham, R., Xu, L., & Wu, W. (2025). Robust Estimation of Unsteady Beat-to-Beat Systolic Blood Pressure Trends Using Photoplethysmography Contextual Cycles. Sensors, 25(12), 3625. https://doi.org/10.3390/s25123625
Vancouver
Huang X, Zhang X, Millham R, Xu L, Wu W. Robust Estimation of Unsteady Beat-to-Beat Systolic Blood Pressure Trends Using Photoplethysmography Contextual Cycles. Sensors. 2025;25(12):3625. doi:10.3390/s25123625
BibTeX
@article{Huang2025,
author = {Huang, Xinyi and Zhang, Xianbin and Millham, Richard and Xu, Lin and Wu, Wanqing},
title = {Robust Estimation of Unsteady Beat-to-Beat Systolic Blood Pressure Trends Using Photoplethysmography Contextual Cycles},
journal = {Sensors},
year = {2025},
volume = {25},
number = {12},
pages = {3625},
doi = {10.3390/s25123625}
}
EUVIMED