MOT: A Low-Latency, Multichannel Wireless Surface Electromyography Acquisition System Based on the AD8232 Front-End
Sensors · 07.06.2025 · 25 (12) · 3600
DOI: 10.3390/s25123600 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 07.06.2025. Verfasst von Augusto Tetsuo Prado Inafuco und 4 weiteren Autor:innen. Beteiligte Einrichtung: Graduate Program in Electrical and Computing Engineering, Federal University of Technology, Curitiba 80230-901, PR, Brazil. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - Brasil (CAPES), Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES).
Abstract (Originalsprache)
Commercial wearable systems for surface electromyography (sEMG) acquisition often trade bandwidth, synchronization, and battery life for miniaturization, and their proprietary designs inhibit reproducibility and cost-effective customization. To address these limitations, we developed MOT, a fully wireless, multichannel platform built from commodity components that can be replicated in academic laboratories. Each sensor node integrates an AD8232 analog front-end configured for 19–690 Hz bandwidth (59 dB mid-band gain) with a 12-bit successive approximation ADC sampling at 1 kS/s. Packets of 120 samples are broadcast via the low-latency ESP-NOW 2.45 GHz protocol to a central hub, which timestamps and streams data to a host PC over USB-UART. Bench tests confirmed the analog response and showed mains interference at least 40 dB below voluntary contraction levels; the cumulative packet loss remained below 0.5% for six simultaneous channels at 100 m line-of-sight, with end-to-end latency under 3 ms. A 180 mAh Li-ion cell was used to power each node for 1.8 h of continuous operation at 100 mA average draw, and the complete sensor, including enclosure, was found to weigh 22 g. MOT reduced a 60 Hz artifact magnitude by up to 22 dB while preserving signal bandwidth. The hardware, therefore, provides a compact and economical solution for biomechanics, rehabilitation, and human–machine interface research that demands mobile, high-fidelity sEMG acquisition.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Graduate Program in Electrical and Computing Engineering, Federal University of Technology, Curitiba 80230-901, PR, Brazil.
- Department of Electronics, Federal University of Technology, Curitiba 80230-901, PR, Brazil.
- Graduate Program in Biomedical Engineering, Federal University of Technology, Curitiba 80230-901, PR, Brazil.
- Department of Informatics, Federal University of Technology, Apucarana 86812-460, PR, Brazil.
ORCID-Profile: Daniel Prado Campos, Sergio Francisco Pichorim, José Jair Alves Mendes Junior
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - Brasil (CAPES)
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior—Brasil (CAPES)
Zitieren
APA
Inafuco, A. T. P., Machoski, P., Campos, D. P., Pichorim, S. F., & Mendes Junior, J. J. A. (2025). MOT: A Low-Latency, Multichannel Wireless Surface Electromyography Acquisition System Based on the AD8232 Front-End. Sensors, 25(12), 3600. https://doi.org/10.3390/s25123600
Vancouver
Inafuco ATP, Machoski P, Campos DP, Pichorim SF, Mendes Junior JJA. MOT: A Low-Latency, Multichannel Wireless Surface Electromyography Acquisition System Based on the AD8232 Front-End. Sensors. 2025;25(12):3600. doi:10.3390/s25123600
BibTeX
@article{Inafuco2025,
author = {Inafuco, Augusto Tetsuo Prado and Machoski, Pablo and Campos, Daniel Prado and Pichorim, Sergio Francisco and Mendes Junior, José Jair Alves},
title = {MOT: A Low-Latency, Multichannel Wireless Surface Electromyography Acquisition System Based on the AD8232 Front-End},
journal = {Sensors},
year = {2025},
volume = {25},
number = {12},
pages = {3600},
doi = {10.3390/s25123600}
}
EUVIMED