An EMG-Based GRU Model for Estimating Foot Pressure to Support Active Ankle Orthosis Development
Sensors · 2025
DOI: 10.3390/s25113558 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Praveen Nuwantha Gunaratne und 1 weiteren Autor:innen. Beteiligte Einrichtung: Interdisciplinary Graduate School of Agriculture and Engineering, University of Miyazaki, 1-1 Gakuen Kibanadai-nishi, Miyazaki 889-2192, Japan. Hauptthemen laut MEDLINE: Electromyography, Foot, Foot Orthoses. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Science and Technology Agency, JST SPRING.
Abstract (Originalsprache)
As populations age, particularly in countries like Japan, mobility impairments related to ankle joint dysfunction, such as foot drop, instability, and reduced gait adaptability, have become a significant concern. Active ankle–foot orthoses (AAFO) offer targeted support during walking; however, most existing systems rely on rule-based or threshold-based control, which are often limited to sagittal plane movements and lacking adaptability to subject-specific gait variations. This study proposes an approach driven by neuromuscular activation using surface electromyography (EMG) and a Gated Recurrent Unit (GRU)-based deep learning model to predict plantar pressure distributions at the heel, midfoot, and toe regions during gait. EMG signals were collected from four key ankle muscles, and plantar pressures were recorded using a customized sandal-integrated force-sensitive resistor (FSR) system. The data underwent comprehensive preprocessing and segmentation using a sliding window method. Root mean square (RMS) values were extracted as the primary input feature due to their consistent performance in capturing muscle activation intensity. The GRU model successfully generalized across subjects, enabling the accurate real-time inference of critical gait events such as heel strike, mid-stance, and toe off. This biomechanical evaluation demonstrated strong signal compatibility, while also identifying individual variations in electromechanical delay (EMD). The proposed predictive framework offers a scalable and interpretable approach to improving real-time AAFO control by synchronizing assistance with user-specific gait dynamics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Interdisciplinary Graduate School of Agriculture and Engineering, University of Miyazaki, 1-1 Gakuen Kibanadai-nishi, Miyazaki 889-2192, Japan.
- Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibanadai-nishi, Miyazaki 889-2192, Japan.
ORCID-Profile: Praveen Nuwantha Gunaratne, Hiroki Tamura
Förderung
- Japan Science and Technology Agency
- JST SPRING
Zitieren
APA
Gunaratne, P. N., & Tamura, H. (2025). An EMG-Based GRU Model for Estimating Foot Pressure to Support Active Ankle Orthosis Development. Sensors. https://doi.org/10.3390/s25113558
Vancouver
Gunaratne PN, Tamura H. An EMG-Based GRU Model for Estimating Foot Pressure to Support Active Ankle Orthosis Development. Sensors. 2025. doi:10.3390/s25113558
BibTeX
@article{Gunaratne2025,
author = {Gunaratne, Praveen Nuwantha and Tamura, Hiroki},
title = {An EMG-Based GRU Model for Estimating Foot Pressure to Support Active Ankle Orthosis Development},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25113558}
}