Validity of a Single Inertial Measurement Unit to Measure Hip Range of Motion During Gait in Patients Undergoing Total Hip Arthroplasty
Sensors · 27.05.2025 · 25 (11) · 3363
DOI: 10.3390/s25113363 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 27.05.2025. Verfasst von Noor Alalem und 5 weiteren Autor:innen. Beteiligte Einrichtung: Kinesiology Laboratory, Geneva University Hospitals and University of Geneva, 1205 Geneva, Switzerland. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Range of Motion, Articular, Gait, Hip Joint. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fondation pour la recherche ostéo-articulaire of Geneva, ESKAS Swiss ExcellenceScholarship, Division of Orthopaedic Surgery and Musculoskeletal Trauma Care of the Geneva University Hospitals.
Abstract (Originalsprache)
Hip flexion range of motion (ROM) during gait is an important surgery outcome for patients undergoing total hip arthroplasty (THA) that could help patient monitoring and rehabilitation. To allow systematic measurements during patients’ clinical pathways, hip ROM measurement should be as simple and cheap as possible to ensure patient and clinician acceptance. Single IMU options can match these requirements and offer measurements both during daily living conditions and standardized clinical tests (e.g., 10 m walk, timed up-and-go). However, single-IMU approaches to measure hip ROM have been limited. Thus, the objective of this study was to explore the accuracy of one IMU in measuring hip ROM during gait and to determine whether a single-IMU approach can provide results comparable to those of multi-IMU systems. To assess this, machine learning models were employed, ranging from the simplest (linear regression) to more complex approaches (artificial neural networks). Eighteen patients undergoing THA and seven controls were measured using a 3D opto-electronic motion capture system and one thigh-mounted IMU. Hip ROM was predicted from thigh ROM using regression and classification models and was compared to the reference hip ROM. Multiple regression was the best-performing model, with limits of agreement (LoA) of ±13° and a systematic bias of 0. Random forest, RNN, GRU and LSTM models yielded LoA ranges > 27.8°, exceeding the threshold of acceptable error. These results showed that one IMU can measure hip ROM with errors comparable to those of two-IMU methods, with potential for improvement. Using multiple linear regression was sufficient and more appropriate than employing complex ANN models. This approach offers simplicity and acceptance to users in clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Kinesiology Laboratory, Geneva University Hospitals and University of Geneva, 1205 Geneva, Switzerland.
- Center of Research on Skeletal Muscle and Movement, Geneva University Hospitals and University of Geneva, 1205 Geneva, Switzerland.
- Division of Orthopaedics and Traumatology, Faculty of Medicine, Geneva University Hospitals, 1205 Geneva, Switzerland.
ORCID-Profile: Noor Alalem, Xavier Gasparutto, Kevin Rose-Dulcina, Peter DiGiovanni, Didier Hannouche, Stéphane Armand
Förderung
- Fondation pour la recherche ostéo-articulaire of Geneva
- ESKAS Swiss ExcellenceScholarship
- Division of Orthopaedic Surgery and Musculoskeletal Trauma Care of the Geneva University Hospitals
- ESKAS Swiss Excellence Scholarship
- “Fondation pour la recherche ostéo-articulaire” of Geneva
Zitieren
APA
Alalem, N., Gasparutto, X., Rose-Dulcina, K., DiGiovanni, P., Hannouche, D., & Armand, S. (2025). Validity of a Single Inertial Measurement Unit to Measure Hip Range of Motion During Gait in Patients Undergoing Total Hip Arthroplasty. Sensors, 25(11), 3363. https://doi.org/10.3390/s25113363
Vancouver
Alalem N, Gasparutto X, Rose-Dulcina K, DiGiovanni P, Hannouche D, Armand S. Validity of a Single Inertial Measurement Unit to Measure Hip Range of Motion During Gait in Patients Undergoing Total Hip Arthroplasty. Sensors. 2025;25(11):3363. doi:10.3390/s25113363
BibTeX
@article{Alalem2025,
author = {Alalem, Noor and Gasparutto, Xavier and Rose-Dulcina, Kevin and DiGiovanni, Peter and Hannouche, Didier and Armand, Stéphane},
title = {Validity of a Single Inertial Measurement Unit to Measure Hip Range of Motion During Gait in Patients Undergoing Total Hip Arthroplasty},
journal = {Sensors},
year = {2025},
volume = {25},
number = {11},
pages = {3363},
doi = {10.3390/s25113363}
}
EUVIMED