EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Criterion and Construct Validity of the Pocket-Worn RISE Device to Assess Movement Behaviour in Community-Dwelling People with Stroke

Camille F M Biemans iD, Laura van der Heiden iD, Cindy Veenhof, Olaf W Verschuren iD, Johanna M A Visser-Meily, Martijn F Pisters iD, Yvonne A W Hartman iD

Sensors · 2025

DOI: 10.3390/s25113308 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Camille F M Biemans und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation, Physiotherapy Science & Sport, UMC Utrecht Brain Centre, University Medical Centre Utrecht, Utrecht University, 3584 CX…. Hauptthemen laut MEDLINE: Stroke, Exercise, Wearable Electronic Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Dutch Research Council (NWO), Nationaal Regieorgaan Praktijkgericht Onderzoek SIA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate monitoring of physical activity (PA) and sedentary behaviour (SB) is crucial for tailoring interventions aimed at improving movement behaviour. This study evaluated the validity of the pocket-worn RISE device for measuring movement behaviour in community-dwelling patients with stroke. Criterion validity was assessed in a laboratory setting using video recordings. Construct validity was assessed in a free-living setting using the thigh-affixed ActivPAL. In the laboratory setting (25 participants, 66 ± 11.8 years), the RISE device showed good criterion validity for SB and PA. In the free-living setting (19 participants, 73 ± 10.2 years), the RISE device showed good construct validity for SB and PA, though further improvements could enhance the accuracy of individual-level measurements of moderate to vigorous physical activity (MVPA) and prolonged sedentary bouts. The mean absolute percentage error and mean percentage error were below the predefined 20% threshold for SB and PA. Intraclass correlation coefficients (ICCs) for SB and PA showed good reliability, but ICC ranges for prolonged sedentary bouts and MVPA were too broad to draw firm conclusions. These findings indicate the RISE device is well-suited for measuring SB and PA in free-living conditions. With real-time feedback, app compatibility, and pocket-wear convenience, the RISE device shows potential for behavioural interventions targeting movement behaviour in stroke and other chronic conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StrokeExerciseWearable Electronic DevicesHumansAgedMaleFemaleIndependent LivingMovementSedentary BehaviorMiddle AgedAged, 80 and overReproducibility of ResultsAccelerometryStroke Rehabilitation

Stichwörter der Autor:innen

accelerometryphysical activitysedentary behaviourvaliditywearable electronic devices

Autor:innen und Institutionen

  • Department of Rehabilitation, Physiotherapy Science & Sport, UMC Utrecht Brain Centre, University Medical Centre Utrecht, Utrecht University, 3584 CXUtrecht, The Netherlands.
  • Research Group Empowering Healthy Behaviour, Department of Health Innovations and Technology, School of Health Sciences, Fontys University of Applied Sciences Physiotherapy, 5612 MA Eindhoven, The Netherlands.
  • Centre for Physiotherapy Research and Innovation in Primary Care, Julius Health Care Centres, 3541 CD Utrecht, The Netherlands.
  • Research Group Innovation of Human Movement Care, HU University of Applied Sciences, 3584 CS Utrecht, The Netherlands.
  • Center of Excellence for Rehabilitation Medicine, UMC Utrecht Brain Center and De Hoogstraat Rehabilitation, 3583 TM Utrecht, The Netherlands.

ORCID-Profile: Camille F M Biemans, Laura van der Heiden, Olaf W Verschuren, Martijn F Pisters, Yvonne A W Hartman

Förderung

  • Dutch Research Council (NWO)
  • Nationaal Regieorgaan Praktijkgericht Onderzoek SIA

Zitieren

APA

Biemans, C. F. M., van der Heiden, L., Veenhof, C., Verschuren, O. W., Visser-Meily, J. M. A., Pisters, M. F., & Hartman, Y. A. W. (2025). Criterion and Construct Validity of the Pocket-Worn RISE Device to Assess Movement Behaviour in Community-Dwelling People with Stroke. Sensors. https://doi.org/10.3390/s25113308

Vancouver

Biemans CFM, van der Heiden L, Veenhof C, Verschuren OW, Visser-Meily JMA, Pisters MF, et al. Criterion and Construct Validity of the Pocket-Worn RISE Device to Assess Movement Behaviour in Community-Dwelling People with Stroke. Sensors. 2025. doi:10.3390/s25113308

BibTeX
@article{Biemans2025,
  author = {Biemans, Camille F M and van der Heiden, Laura and Veenhof, Cindy and Verschuren, Olaf W and Visser-Meily, Johanna M A and Pisters, Martijn F and Hartman, Yvonne A W},
  title = {Criterion and Construct Validity of the Pocket-Worn RISE Device to Assess Movement Behaviour in Community-Dwelling People with Stroke},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25113308}
}
Kostenlos starten →