EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-Invasive Estimation of Arterial Stiffness Using Photoplethysmography Sensors: An In Vitro Approach

Gianluca Diana iD, Francesco Scardulla, Silvia Puleo iD, Salvatore Pasta iD, Leonardo D'Acquisto iD

Sensors · 24.05.2025 · 25 (11) · 3301

DOI: 10.3390/s25113301 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 24.05.2025. Verfasst von Gianluca Diana und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering, University of Palermo, Viale delle Scienze, Ed. 8, 90128 Palermo, Italy. Hauptthemen laut MEDLINE: Photoplethysmography, Vascular Stiffness. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With advancing age, blood vessels undergo deterioration that causes structural and functional changes, including a progressive increase in arterial wall stiffness. Since arterial stiffness is closely linked to the potential risks of cardiovascular diseases, which remains the leading cause of global mortality, it has become essential to develop effective techniques for early diagnosis and continuous monitoring over time. Photoplethysmography, a low-cost and non-invasive technology that measures blood volume changes, has gained increasing popularity in recent years and has proven to be a potential valuable tool for estimating arterial stiffness. This study employs an in vitro experimental setup designed to simulate the cardiovascular system performing under controlled velocity and pressure conditions, in which silicone phantom models with different geometric and mechanical properties were implemented to evaluate their stiffness using a pair of photoplethysmographic sensors. These were employed to measure the pulse wave velocity, currently considered the reference technique for estimating arterial stiffness, correlated through the well-known Moens–Korteweg equation. Photoplethysmographic sensors were placed at three specific distances to determine an optimal configuration for assessing arterial stiffness. Results showed the best performance for softer vascular models at a 15 cm sensor distance, with measurements demonstrating satisfactory accuracy. Variability and standard deviation values increased with model stiffness. The aim of this study is to improve the use of photoplethysmographic sensors for monitoring the mechanical properties of blood vessels and, therefore, to prevent potential cardiovascular diseases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotoplethysmographyVascular StiffnessHumansPulse Wave AnalysisCardiovascular Diseases

Stichwörter der Autor:innen

Young’s modulusarterial stiffnessexperimental setupoptical sensorsphotoplethysmography (PPG)pulse wave velocity

Autor:innen und Institutionen

  • Department of Engineering, University of Palermo, Viale delle Scienze, Ed. 8, 90128 Palermo, Italy.

ORCID-Profile: Gianluca Diana, Silvia Puleo, Salvatore Pasta, Leonardo D'Acquisto

Zitieren

APA

Diana, G., Scardulla, F., Puleo, S., Pasta, S., & D'Acquisto, L. (2025). Non-Invasive Estimation of Arterial Stiffness Using Photoplethysmography Sensors: An In Vitro Approach. Sensors, 25(11), 3301. https://doi.org/10.3390/s25113301

Vancouver

Diana G, Scardulla F, Puleo S, Pasta S, D'Acquisto L. Non-Invasive Estimation of Arterial Stiffness Using Photoplethysmography Sensors: An In Vitro Approach. Sensors. 2025;25(11):3301. doi:10.3390/s25113301

BibTeX
@article{Diana2025,
  author = {Diana, Gianluca and Scardulla, Francesco and Puleo, Silvia and Pasta, Salvatore and D'Acquisto, Leonardo},
  title = {Non-Invasive Estimation of Arterial Stiffness Using Photoplethysmography Sensors: An In Vitro Approach},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {11},
  pages = {3301},
  doi = {10.3390/s25113301}
}
Kostenlos starten →