Custom-Designed Portable Potentiostat and Indirect Cyclic Voltammetry Index Analysis for Rapid Pesticide Detection Using Molecularly Imprinted Polymer Sensors
Sensors · 2025
DOI: 10.3390/s25102999 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Min-Wei Hung und 6 weiteren Autor:innen. Beteiligte Einrichtung: National Center for Instrumentation Research, National Institutes of Applied Research, Hsinchu 300092, Taiwan. Hauptthemen laut MEDLINE: Pesticides, Molecularly Imprinted Polymers, Electrochemical Techniques, Molecular Imprinting. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This study was supported by the National Science and Technology Council of Taiwan (grant no. NSTC 112-2622-E-492-004) and the I-Dream Project of the National I…, National Science and Technology Council of Taiwan, I-Dream Project of the National Institutes of Applied Research.
Abstract (Originalsprache)
Water pesticide contamination represents a major threat to ecological systems and public health, particularly in agricultural regions. Although conventional detection methods such as liquid chromatography and electrochemical analysis are highly accurate, they are expensive, require skilled operators, and cannot provide real-time results. This study developed a portable miniaturized electrochemical analysis platform based on cyclic voltammetry (CV) for rapid pesticide detection. The platform was compared with a commercial electrochemical analyzer and yielded similar performance in detecting chlorpyrifos at different concentrations. When ultrapure water was used as the background solution, the total area under the CV curve exhibited a linear correlation (R2 = 0.89) with the pesticide concentration, indicating its potential as a characteristic index. When molecularly imprinted polymers were added, the platform achieved a limit of detection of 50 ppm, with the area under the CV curve maintaining a logarithmic linear relationship (R2 = 0.98) with the pesticide concentration. These findings confirm the total area under the CV curve as the most reliable characteristic index for pesticide quantification. Overall, the proposed platform offers portability, straightforward operation, cost-effectiveness, and expandability, making it promising for on-site environmental monitoring. By incorporating GPS functionality, the platform can provide real-time pesticide concentration mapping, supporting its use in precision agriculture and water quality management.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- National Center for Instrumentation Research, National Institutes of Applied Research, Hsinchu 300092, Taiwan.
- National Metal and Materials Technology Center, Pathum Thani 12120, Thailand.
ORCID-Profile: Hsin-Yi Tsai
Förderung
- This study was supported by the National Science and Technology Council of Taiwan (grant no. NSTC 112-2622-E-492-004) and the I-Dream Project of the National I…
- National Science and Technology Council of Taiwan
- I-Dream Project of the National Institutes of Applied Research
Zitieren
APA
Hung, M. W., Lee, C. J., Lin, Y. H., Chao, L. C., Huang, K. C., Tsai, H. Y., & Thanachayanont, C. (2025). Custom-Designed Portable Potentiostat and Indirect Cyclic Voltammetry Index Analysis for Rapid Pesticide Detection Using Molecularly Imprinted Polymer Sensors. Sensors. https://doi.org/10.3390/s25102999
Vancouver
Hung MW, Lee CJ, Lin YH, Chao LC, Huang KC, Tsai HY, et al. Custom-Designed Portable Potentiostat and Indirect Cyclic Voltammetry Index Analysis for Rapid Pesticide Detection Using Molecularly Imprinted Polymer Sensors. Sensors. 2025. doi:10.3390/s25102999
BibTeX
@article{Hung2025,
author = {Hung, Min-Wei and Lee, Chen-Ju and Lin, Yu-Hsuan and Chao, Liang-Chieh and Huang, Kuo-Cheng and Tsai, Hsin-Yi and Thanachayanont, Chanchana},
title = {Custom-Designed Portable Potentiostat and Indirect Cyclic Voltammetry Index Analysis for Rapid Pesticide Detection Using Molecularly Imprinted Polymer Sensors},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25102999}
}
EUVIMED