Übersichtsarbeit in der Zeitschrift Sensors, online erschienen am 09.05.2025. Verfasst von Jorge Medina-Avelino und 2 weiteren Autor:innen. Beteiligte Einrichtung: Software Engineering Department, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18071 Granada, Sp…. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Electrocardiography. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Granada, University of Pacifico.
Abstract (Originalsprache)
The increasing focus on improving care for high-cost patients has highlighted the potential of Hospital at Home (HaH) and remote patient monitoring (RPM) programs to optimize patient outcomes while reducing healthcare costs. This paper examines the role of wearable devices with electrocardiogram (ECG) capabilities for continuous cardiac monitoring, a crucial aspect for the timely detection and management of various cardiac conditions. The functionality of current wearable technology is scrutinized to determine its effectiveness in meeting clinical needs, employing a proposed ABCD guide (accuracy, benefit, compatibility, and data governance) for evaluation. While smartwatches show promise in detecting arrhythmias like atrial fibrillation, their broader diagnostic capabilities, including the potential for monitoring corrected QT (QTc) intervals during pharmacological interventions and approximating multi-lead ECG information for improved myocardial infarction detection, are also explored. Recent advancements in machine learning and deep learning for cardiac health monitoring are highlighted, alongside persistent challenges, particularly concerning signal quality and the need for further validation for widespread adoption in older adults and Hospital at Home settings. Ongoing improvements are necessary to overcome current limitations and fully realize the potential of wearable ECG technology in providing optimal care for high-risk patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Software Engineering Department, Research Centre for Information and Communication Technologies (CITIC-UGR), University of Granada, 18071 Granada, Spain.
- Faculty of Technology and Innovation, University of Pacifico, Guayaquil 090904, Ecuador.
- Department of Computing Sciences University of Villanova, Villanova, PA 19085, USA.
ORCID-Profile: Jorge Medina-Avelino, Ricardo Silva-Bustillos, Juan A Holgado-Terriza
Förderung
- University of Granada
- University of Pacifico
Zitieren
APA
Medina-Avelino, J., Silva-Bustillos, R., & Holgado-Terriza, J. A. (2025). Are Wearable ECG Devices Ready for Hospital at Home Application?. Sensors, 25(10), 2982. https://doi.org/10.3390/s25102982
Vancouver
Medina-Avelino J, Silva-Bustillos R, Holgado-Terriza JA. Are Wearable ECG Devices Ready for Hospital at Home Application?. Sensors. 2025;25(10):2982. doi:10.3390/s25102982
BibTeX
@article{MedinaAvelino2025,
author = {Medina-Avelino, Jorge and Silva-Bustillos, Ricardo and Holgado-Terriza, Juan A},
title = {Are Wearable ECG Devices Ready for Hospital at Home Application?},
journal = {Sensors},
year = {2025},
volume = {25},
number = {10},
pages = {2982},
doi = {10.3390/s25102982}
}
EUVIMED