EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

AgNPs@CeO2/Nafion Nanocomposite-Modified Electrode for the Sensitive Detection of Trace Lead (II) in Water Samples

Zhengying Guo, Peng Xu, Shiqing Zhou, Ruoxi Wu iD

Sensors · 23.04.2025 · 25 (9) · 2655

DOI: 10.3390/s25092655 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 23.04.2025. Verfasst von Zhengying Guo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Engineering Research Center of Water Security Technology and Application, College of Civil Engineering, Hunan University, Changsha 410082, Chin…. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Excessive levels of heavy metal pollutants in the environment pose significant threats to human health and ecosystem stability. Consequently, the accurate and rapid detection of heavy metal ions is critically important. A AgNPs@CeO2/Nafion composite was prepared by dispersing nano-ceria (CeO2) in a Nafion solution and incorporating silver nanoparticles (AgNPs). The morphology, microstructure, and electrochemical properties of the modified electrode materials were systematically characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD), and cyclic voltammetry (CV). By leveraging the oxygen vacancies and high electron transfer efficiency of CeO2, the strong adsorption capacity of Nafion, and the superior conductivity of AgNPs, an AgNPs@CeO2/Nafion/GCE electrochemical sensor was developed. Under optimized conditions, trace Pb2+ in water was detected using square wave anodic stripping voltammetry (SWASV). The sensor demonstrated a linear response for Pb2+ within the concentration range of 1–100 μg·L−1, with a detection limit of 0.17 μg·L−1 (S/N = 3). When applied to real water samples, the method achieved recovery rates between 93.7% and 110.3%, validating its reliability and practical applicability.

Schlagwörter

Stichwörter der Autor:innen

AgNPsNafion-modified electrodelead (II)nano-ceria (CeO2)sensor

Autor:innen und Institutionen

  • Hunan Engineering Research Center of Water Security Technology and Application, College of Civil Engineering, Hunan University, Changsha 410082, China.
  • Department of Water Engineering and Science, College of Civil Engineering, Hunan University, Changsha 410082, China.

ORCID-Profile: Ruoxi Wu

Zitieren

APA

Guo, Z., Xu, P., Zhou, S., & Wu, R. (2025). AgNPs@CeO2/Nafion Nanocomposite-Modified Electrode for the Sensitive Detection of Trace Lead (II) in Water Samples. Sensors, 25(9), 2655. https://doi.org/10.3390/s25092655

Vancouver

Guo Z, Xu P, Zhou S, Wu R. AgNPs@CeO2/Nafion Nanocomposite-Modified Electrode for the Sensitive Detection of Trace Lead (II) in Water Samples. Sensors. 2025;25(9):2655. doi:10.3390/s25092655

BibTeX
@article{Guo2025,
  author = {Guo, Zhengying and Xu, Peng and Zhou, Shiqing and Wu, Ruoxi},
  title = {AgNPs@CeO2/Nafion Nanocomposite-Modified Electrode for the Sensitive Detection of Trace Lead (II) in Water Samples},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {9},
  pages = {2655},
  doi = {10.3390/s25092655}
}
Kostenlos starten →