High Concordance of E-Nose-Derived Breathprints in a Healthy Population: A Cross-Sectional Observational Study
Sensors · 20.04.2025 · 25 (8) · 2610
DOI: 10.3390/s25082610 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Sensors, online erschienen am 20.04.2025. Verfasst von Silvano Dragonieri und 4 weiteren Autor:innen. Beteiligte Einrichtung: Respiratory Diseases, University of Bari "Aldo Moro", 70121 Bari, Italy. Hauptthemen laut MEDLINE: Electronic Nose. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Exhaled breath analysis using electronic noses (e-noses) is a promising non-invasive diagnostic tool. However, a lack of standardized protocols limits clinical implementation. This study evaluates the consistency of breathprints in healthy subjects using the Cyranose 320 e-nose to support standardization efforts. Breath samples from 139 healthy non-smoking subjects (age range 18–65 years) were collected using a standardized protocol. Participants exhaled into a Tedlar bag for immediate analysis with the Cyranose 320. Principal Component Analysis (PCA) was used to reduce data dimensionality, and K-means clustering grouped subjects based on breathprints. PCA identified four principal components explaining 97.15% of variance. K-means clustering revealed two clusters: 1 outlier and 138 subjects with highly similar breathprints. The median distance from the cluster center was 0.21 (IQR: 0.18–0.24), indicating low variability. Box plots confirmed breathprint consistency across subjects. The high consistency of breathprints in healthy subjects supports the feasibility of standardizing e-nose protocols. These findings highlight the potential of e-noses for clinical diagnostics, warranting further research in diverse populations and disease cohorts.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Respiratory Diseases, University of Bari "Aldo Moro", 70121 Bari, Italy.
ORCID-Profile: Silvano Dragonieri
Zitieren
APA
Dragonieri, S., Quaranta, V. N., Portacci, A., Ranieri, T., & Carpagnano, G. E. (2025). High Concordance of E-Nose-Derived Breathprints in a Healthy Population: A Cross-Sectional Observational Study. Sensors, 25(8), 2610. https://doi.org/10.3390/s25082610
Vancouver
Dragonieri S, Quaranta VN, Portacci A, Ranieri T, Carpagnano GE. High Concordance of E-Nose-Derived Breathprints in a Healthy Population: A Cross-Sectional Observational Study. Sensors. 2025;25(8):2610. doi:10.3390/s25082610
BibTeX
@article{Dragonieri2025,
author = {Dragonieri, Silvano and Quaranta, Vitaliano Nicola and Portacci, Andrea and Ranieri, Teresa and Carpagnano, Giovanna Elisiana},
title = {High Concordance of E-Nose-Derived Breathprints in a Healthy Population: A Cross-Sectional Observational Study},
journal = {Sensors},
year = {2025},
volume = {25},
number = {8},
pages = {2610},
doi = {10.3390/s25082610}
}