Fachartikel in der Zeitschrift Sensors, online erschienen am 05.04.2025. Verfasst von Hongfei Hou und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Chemical Engineering, Ningbo University, Ningbo 315211, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China, National Natural Science Foundation of China, Chinese Academy of Sciences Youth Innovation Promotion Association.
Abstract (Originalsprache)
Flexible magnetic tactile sensors hold transformative potential in robotics and human–computer interactions by enabling precise force detection. However, existing sensors face challenges in balancing sensitivity, detection range, and structural adaptability for sensing force. This study proposed a pre-compressed magnetization method to address these limitations by amplifying the magnetoelastic effect through optimized magnetization direction distribution of the elastomer. A body-centered cubic lattice-structured magnetoelastomer featuring regular deformation under compression was fabricated via digital light processing (DLP) to validate this method. Finite element simulations and experimental analyses revealed that magnetizing the material under 60% compression strain optimized magnetization direction distribution, enhancing force–magnetic coupling. Integrating the magnetic elastomer with a hall sensor, the prepared tactile sensor demonstrated a low detection limit (1 mN), wide detection range (0.001–10 N), rapid response/recovery times (40 ms/50 ms), and durability (>1500 cycles). By using machine learning, the sensor enabled accurate 3D force prediction.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Materials Science and Chemical Engineering, Ningbo University, Ningbo 315211, China.
- CAS Key Laboratory of Magnetic Materials and Devices, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China.
- Zhejiang Province Key Laboratory of Magnetic Materials and Application Technology, Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China.
- College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, Beijing 100049, China.
ORCID-Profile: Ziyin Xiang, Xiaohui Yi, Jie Shang
Förderung
- National Key R&D Program of China
- National Natural Science Foundation of China
- Chinese Academy of Sciences Youth Innovation Promotion Association
- International Partnership Program of Chinese Academy of Sciences
- Talent Plan of Shanghai Branch, Chinese Academy of Sciences
- Project of Zhejiang Province
- Natural Science Foundation of Zhejiang Province
- Ningbo Technology Project
Zitieren
APA
Hou, H., Xiang, Z., Zhi, C., Hu, H., Zhu, X., Bian, B., Wu, Y., Liu, Y., Yi, X., Shang, J., & Li, R. W. (2025). Optimized Magnetization Distribution in Body-Centered Cubic Lattice-Structured Magnetoelastomer for High-Performance 3D Force–Tactile Sensors. Sensors, 25(7), 2312. https://doi.org/10.3390/s25072312
Vancouver
Hou H, Xiang Z, Zhi C, Hu H, Zhu X, Bian B, et al. Optimized Magnetization Distribution in Body-Centered Cubic Lattice-Structured Magnetoelastomer for High-Performance 3D Force–Tactile Sensors. Sensors. 2025;25(7):2312. doi:10.3390/s25072312
BibTeX
@article{Hou2025,
author = {Hou, Hongfei and Xiang, Ziyin and Zhi, Chaonan and Hu, Haodong and Zhu, Xingyu and Bian, Baoru and Wu, Yuanzhao and Liu, Yiwei and Yi, Xiaohui and Shang, Jie and Li, Run-Wei},
title = {Optimized Magnetization Distribution in Body-Centered Cubic Lattice-Structured Magnetoelastomer for High-Performance 3D Force–Tactile Sensors},
journal = {Sensors},
year = {2025},
volume = {25},
number = {7},
pages = {2312},
doi = {10.3390/s25072312}
}
EUVIMED