EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Partial Discharge Detection Approach in Distribution Cabinets Using a Mach–Zehnder Interferometer

Junliang Wang, Ying Zhang iD, Xiang Gu

Sensors · 03.04.2025 · 25 (7) · 2265

DOI: 10.3390/s25072265 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 03.04.2025. Verfasst von Junliang Wang und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Microelectronics, Nanjing University of Science and Technology, Nanjing 210094, China. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Anhui Province Natural Science Foundation of China, the Foundation of Anhui Key Laboratory of Industrial Energy-Saving and Safety, Anhui Collaborative Innovation Center of Industrial Energy-Saving and Power Qual….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Distribution cabinets are of paramount importance in power supply systems. Internal partial discharge may result in power interruption or even the outbreak of fire. This paper proposes a partial discharge (PD) detection approach based on a fiber-optic Mach–Zehnder interferometer (MZI). The MZI method utilizes a fiber wound with a certain size and number of turns as the sensing element, which is mounted on the wall of the low-voltage distribution cabinet to monitor the partial discharge within the cabinet in real time. A true-type distribution cabinet partial discharge experimental platform is developed to validate the proposed method. Three 10 m long fiber-optic sensors with diameters of 50 mm, 80 mm, and 100 mm are designed and compared with a traditional piezoelectric transducer (PZT) for analysis. The experimental results indicate that the fiber-optic MZI sensor can effectively capture PD acoustic pulses, and the pulse amplitude is consistent with that of the PZT sensor. Moreover, compared with the PZT sensor, the fiber-optic MZI system possesses a higher frequency response and a longer effective detection time for PD pulses, demonstrating superior PD detection performance. The fiber-optic coil sensor with a diameter of 8 cm performed optimally in the experiment. The fiber-optic sensing method based on the MZI has significant potential application value in the partial discharge detection of power distribution cabinets, providing a theoretical basis for its application in engineering practice.

Schlagwörter

Stichwörter der Autor:innen

Mach–Zehnder interferometerdistribution cabinetspartial dischargeultrasonic waves

Autor:innen und Institutionen

  • School of Microelectronics, Nanjing University of Science and Technology, Nanjing 210094, China.
  • CMEC Comtrans International Co., Ltd., Beijing 100055, China.

ORCID-Profile: Ying Zhang

Förderung

  • National Natural Science Foundation of China
  • Anhui Province Natural Science Foundation of China
  • the Foundation of Anhui Key Laboratory of Industrial Energy-Saving and Safety, Anhui Collaborative Innovation Center of Industrial Energy-Saving and Power Qual…

Zitieren

APA

Wang, J., Zhang, Y., & Gu, X. (2025). A Partial Discharge Detection Approach in Distribution Cabinets Using a Mach–Zehnder Interferometer. Sensors, 25(7), 2265. https://doi.org/10.3390/s25072265

Vancouver

Wang J, Zhang Y, Gu X. A Partial Discharge Detection Approach in Distribution Cabinets Using a Mach–Zehnder Interferometer. Sensors. 2025;25(7):2265. doi:10.3390/s25072265

BibTeX
@article{Wang2025,
  author = {Wang, Junliang and Zhang, Ying and Gu, Xiang},
  title = {A Partial Discharge Detection Approach in Distribution Cabinets Using a Mach–Zehnder Interferometer},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {7},
  pages = {2265},
  doi = {10.3390/s25072265}
}
Kostenlos starten →