Chemical Nose-Based Non-Invasive Detection of Breast Cancer Using Exhaled Breath
Sensors · 31.03.2025 · 25 (7) · 2210
DOI: 10.3390/s25072210 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 31.03.2025. Verfasst von Yosef Matana und 6 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering, Ben-Gurion University of the Negev, Beersheba 8410501, Israel. Hauptthemen laut MEDLINE: Breast Neoplasms, Electronic Nose. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Breast cancer (BC) is the most commonly occurring cancer in women and one of the leading causes of cancer death in women worldwide. BC mortality is related to early tumor detection, highlighting the importance of early detection methods. This work aims to develop a robust, accurate and highly reliable, non-invasive, low-cost screening method for early detection of BC in routine screening using exhaled breath (EB) analysis. For this, exhaled breath samples were collected from 267 women: 131 breast cancer patients and 136 healthy women. After collection, the samples were measured using a commercially available electronic nose. The signals obtained for each sample were first processed and then went through a feature extraction step. An SVM model was then optimized with respect to the accuracy matrix using a validation set by applying a Monte Carlo cross-validation with 100 iterations, with each iteration containing 20% of the data. The validation set results were 80, 94, 88, and 95% for recall, precision, accuracy, and specificity, correspondingly. Once model optimization had concluded, 22 unknown samples were analyzed by the model, and an accuracy, precision, and specificity of 91% was achieved.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Biomedical Engineering, Ben-Gurion University of the Negev, Beersheba 8410501, Israel.
- Breast Health Center Soroka Medical Center, Ben-Gurion University, Beersheba 8410501, Israel.
- OPTIMAL-Industrial Neural Systems, Beersheba 84243, Israel.
- Pulmonary Unit, Soroka University Medical Center and the Faculty of Health Sciences, Ben-Gurion University of the Negev, Beersheba 8410501, Israel.
- Department of Analytical Chemistry, Nuclear Research Center Negev, Be'er-Sheva 84190, Israel.
ORCID-Profile: Offer Zeiri
Zitieren
APA
Matana, Y., Libson, S., Amihood, B., Boger, Z., Lieberman, D., Zeiri, O., & Zeiri, Y. (2025). Chemical Nose-Based Non-Invasive Detection of Breast Cancer Using Exhaled Breath. Sensors, 25(7), 2210. https://doi.org/10.3390/s25072210
Vancouver
Matana Y, Libson S, Amihood B, Boger Z, Lieberman D, Zeiri O, et al. Chemical Nose-Based Non-Invasive Detection of Breast Cancer Using Exhaled Breath. Sensors. 2025;25(7):2210. doi:10.3390/s25072210
BibTeX
@article{Matana2025,
author = {Matana, Yosef and Libson, Shai and Amihood, Barak and Boger, Zvi and Lieberman, David and Zeiri, Offer and Zeiri, Yehuda},
title = {Chemical Nose-Based Non-Invasive Detection of Breast Cancer Using Exhaled Breath},
journal = {Sensors},
year = {2025},
volume = {25},
number = {7},
pages = {2210},
doi = {10.3390/s25072210}
}