EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validation of a Neurophysiological-Based Wearable Device (Somfit) for the Assessment of Sleep in Athletes

Gregory D Roach iD, Dean J Miller iD, Stephanie J Shell iD, Kathleen H Miles iD, Charli Sargent iD

Sensors · 2025

DOI: 10.3390/s25072123 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Gregory D Roach und 4 weiteren Autor:innen. Beteiligte Einrichtung: Appleton Institute for Behavioural Science, Central Queensland University, Adelaide 4701, Australia. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Athletes, Sleep. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Sports Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of the study was to examine the validity of a neurophysiological-based wearable device, i.e., Somfit (Compumedics Ltd.), for the assessment of sleep in athletes. Twenty-seven athletes (14 F, 13 M, aged 22.3 ± 5.1 years) spent a single night in a sleep laboratory. The participants had 9 h in bed (23:00–08:00) while fitted simultaneously with Somfit and polysomnography (PSG), i.e., the gold standard for the assessment of sleep. Somfit and PSG were used to independently categorise each 30-s epoch of time in bed into one of five states, i.e., wake, stage 1 non-REM sleep (N1), stage 2 non-REM sleep (N2), stage 3 non-REM sleep (N3), or REM sleep. There were large differences between participants in terms of the amount of Somfit data that were successfully captured/scored, so three subsets were considered in the subsequent analyses: unfiltered subset (n = 26)—all participants, except one for whom no Somfit data were captured/scored; good-capture subset (n = 15)—participants for whom > 80% of Somfit data were captured/scored; excellent-capture subset (n = 7)—participants for whom > 99.9% of Somfit data were captured/scored. Agreement for the five-state categorisation of time in bed was calculated as the percentage of PSG epochs correctly scored by Somfit as N1, N2, N3, REM, or wake. Agreement (and Cohen’s kappa) was 63% (0.47) for the unfiltered subset, 66% (0.52) for the good-capture subset, and 79% (0.70) for the excellent-capture subset. These data indicate a moderate–substantial level of agreement between Somfit and PSG for the assessment of sleep in athletes. Wearable devices that can capture valid sleep data may also be used to derive important measures related to the circadian system, such as sleep consistency and social jet lag.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesAthletesSleepHumansMalePolysomnographyFemaleAdultYoung AdultSleep StagesElectroencephalography

Stichwörter der Autor:innen

Bland–Altmanagreementathleteerror matrixpolysomnographysensitivitysleepspecificityvalidationwearable

Autor:innen und Institutionen

  • Appleton Institute for Behavioural Science, Central Queensland University, Adelaide 4701, Australia.
  • Australian Institute of Sport, Australian Sports Commission, Canberra 2617, Australia.
  • School of Medicine and Psychology, The Australian National University, Canberra 2601, Australia.

ORCID-Profile: Gregory D Roach, Dean J Miller, Stephanie J Shell, Kathleen H Miles, Charli Sargent

Förderung

  • Australian Sports Commission

Zitieren

APA

Roach, G. D., Miller, D. J., Shell, S. J., Miles, K. H., & Sargent, C. (2025). Validation of a Neurophysiological-Based Wearable Device (Somfit) for the Assessment of Sleep in Athletes. Sensors. https://doi.org/10.3390/s25072123

Vancouver

Roach GD, Miller DJ, Shell SJ, Miles KH, Sargent C. Validation of a Neurophysiological-Based Wearable Device (Somfit) for the Assessment of Sleep in Athletes. Sensors. 2025. doi:10.3390/s25072123

BibTeX
@article{Roach2025,
  author = {Roach, Gregory D and Miller, Dean J and Shell, Stephanie J and Miles, Kathleen H and Sargent, Charli},
  title = {Validation of a Neurophysiological-Based Wearable Device (Somfit) for the Assessment of Sleep in Athletes},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25072123}
}
Kostenlos starten →