EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Real-Time Monitoring of Personal Protective Equipment Adherence Using On-Device Artificial Intelligence Models

Yam Horesh iD, Renana Oz Rokach iD, Yotam Kolben, Dean Nachman

Sensors · 22.03.2025 · 25 (7) · 2003

DOI: 10.3390/s25072003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 22.03.2025. Verfasst von Yam Horesh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem 9112001, Israel. Hauptthemen laut MEDLINE: Personal Protective Equipment, Artificial Intelligence. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Personal protective equipment (PPE) is crucial for infection prevention and is effective only when worn correctly and consistently. Health organizations often use education or inspections to mitigate non-compliance, but these are costly and have limited success. This study developed a novel on-device, AI-based computer vision system to monitor healthcare worker PPE adherence in real time. Using a custom-built image dataset of 7142 images of 11 participants wearing various combinations of PPE (mask, gloves, gown), we trained a series of binary classifiers for each PPE item. By utilizing a lightweight MobileNetV3 model, we optimized the system for edge computing on a Raspberry Pi 5 single-board computer, enabling rapid image processing without the need for external servers. Our models achieved high accuracy in identifying individual PPE items (93–97%), with an overall accuracy of 85.58 ± 0.82% when all items were correctly classified. Real-time evaluation with 11 unseen medical staff in a cardiac intensive care unit demonstrated the practical viability of our system, maintaining a high per-item accuracy of 87–89%. This study highlights the potential for AI-driven solutions to significantly improve PPE compliance in healthcare settings, offering a cost-effective, efficient, and reliable tool for enhancing patient safety and mitigating infection risks.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Personal Protective EquipmentArtificial IntelligenceHumansHealth Personnel

Stichwörter der Autor:innen

adherence monitoringcomputer visionedge computingpersonal protective equipmentsingle-board computer

Autor:innen und Institutionen

  • Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem 9112001, Israel.
  • Heart Institute, Hadassah Medical Center, Jerusalem 9112001, Israel.

ORCID-Profile: Yam Horesh, Renana Oz Rokach

Zitieren

APA

Horesh, Y., Oz Rokach, R., Kolben, Y., & Nachman, D. (2025). Real-Time Monitoring of Personal Protective Equipment Adherence Using On-Device Artificial Intelligence Models. Sensors, 25(7), 2003. https://doi.org/10.3390/s25072003

Vancouver

Horesh Y, Oz Rokach R, Kolben Y, Nachman D. Real-Time Monitoring of Personal Protective Equipment Adherence Using On-Device Artificial Intelligence Models. Sensors. 2025;25(7):2003. doi:10.3390/s25072003

BibTeX
@article{Horesh2025,
  author = {Horesh, Yam and Oz Rokach, Renana and Kolben, Yotam and Nachman, Dean},
  title = {Real-Time Monitoring of Personal Protective Equipment Adherence Using On-Device Artificial Intelligence Models},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {7},
  pages = {2003},
  doi = {10.3390/s25072003}
}
Kostenlos starten →