Application of Smart Watch-Based Functional Evaluation for Upper Extremity Impairment: A Preliminary Study on Older Emirati Stroke Population
Sensors · 2025
DOI: 10.3390/s25051554 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Yeo Hyung Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Medicine, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea. Hauptthemen laut MEDLINE: Upper Extremity, Stroke Rehabilitation, Stroke. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Seoul National University Hospital, Catholic Medical Center Research Foundation, SNUH Research Fund.
Themen: Schlaganfall
Abstract (Originalsprache)
Smartwatch-based functional assessments for upper extremity movement are a promising tool for a detailed and serial assessment during stroke rehabilitation, but their clinical application remains challenging. In this study, nine patients with hemiparesis due to a stroke participated in occupational therapy sessions using virtual reality-based rehabilitation devices. An Action Research Arm Test (ARAT) was performed at baseline and after intervention, with wrist smartwatch sensors recording motion data. We extracted acceleration and gyro sensor data from smartwatches and calculated the average motion segment size (MSS) as a measure of motion smoothness. Among the included patients, four participants completed all 10 therapy sessions and the follow-up evaluation. The average MSSs of acceleration for all x, y, and z directions were significantly correlated with the ARAT scores across all task domains. For angular motion, the average MSS in the gross movement task (domain 4) showed strong correlations with the ARAT scores: roll (rs = 0.735, p = 0.004), pitch (rs = 0.715, p = 0.009), and yaw (rs = 0.704, p = 0.007). At the serial follow-ups, most participants showed a considerable increase in the average MSSs of the roll, pitch, and yaw angles measured during domain 4, alongside improvements in their clinical ARAT scores. Our findings support the feasibility of using commercial smartwatch-based parameters for upper extremity functional evaluations during stroke rehabilitation and highlight their potential for serial follow-up assessments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Rehabilitation Medicine, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea.
- Department of Rehabilitation Medicine, Sheikh Khalifa Specialty Hospital, Ras al Khaimah 6365, United Arab Emirates.
- Department of Rehabilitation Medicine, Seoul National University Hospital, Seoul 03080, Republic of Korea.
ORCID-Profile: Yeo Hyung Kim, Hyung Seok Nam
Förderung
- Seoul National University Hospital
- Catholic Medical Center Research Foundation
- SNUH Research Fund
Zitieren
APA
Kim, Y. H., Kim, S., & Nam, H. S. (2025). Application of Smart Watch-Based Functional Evaluation for Upper Extremity Impairment: A Preliminary Study on Older Emirati Stroke Population. Sensors. https://doi.org/10.3390/s25051554
Vancouver
Kim YH, Kim S, Nam HS. Application of Smart Watch-Based Functional Evaluation for Upper Extremity Impairment: A Preliminary Study on Older Emirati Stroke Population. Sensors. 2025. doi:10.3390/s25051554
BibTeX
@article{Kim2025,
author = {Kim, Yeo Hyung and Kim, Sarah and Nam, Hyung Seok},
title = {Application of Smart Watch-Based Functional Evaluation for Upper Extremity Impairment: A Preliminary Study on Older Emirati Stroke Population},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25051554}
}
EUVIMED