Assessing the Reliability of a Combat Sports Kick-Time Device
Sensors · 2025
DOI: 10.3390/s25051420 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Johan Robalino und 6 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate Program in Physical Education, Federal University of Mato Grosso, Cuiabá 78060-900, Brazil. Hauptthemen laut MEDLINE: Athletic Performance, Martial Arts. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (Originalsprache)
In combat sports, precise technique evaluation is crucial for performance optimization; however, traditional systems for evaluating kick performance are frequently unreasonably complicated and costly. This study offers a useful and accessible substitute by introducing a contact mat-based tool that measures the roundhouse kick’s execution time during both the attack and recovery phases and by demonstrating its reliability. The experimental sessions involved 16 male Shotokan karate athletes (age: 25.6 ± 7.1 years; height: 1.74 ± 0.05 m; body mass: 71.5 ± 8.7 kg; body fat percentage: 14.7 ± 6.7%; training experience: 11.0 ± 4.9 years). The protocol included four sessions, starting with a familiarization phase followed by three testing sessions (test, retest, and retest two), during which a standardized warm-up was performed along with the roundhouse kick test. The intraclass coefficient correlation (ICC) used indicated high reliability for the at-tack (ICC = 0.85, 95% CI [0.64, 0.94]), recovery (ICC = 0.89, 95% CI [0.75, 0.96]), and total time (ICC = 0.90, 95% CI [0.76, 0.96]). The Friedman test revealed no significant difference between testing sessions (p > 0.31), demonstrating high reliability and no significant differences between sessions. This study confirms the system as a simple and reliability tool for measuring roundhouse-kick timing in combat sports.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Postgraduate Program in Physical Education, Federal University of Mato Grosso, Cuiabá 78060-900, Brazil.
- Centre for Research, Education, Innovation and Intervention in Sport (CIFI2D), Faculty of Sports, University of Porto, 4200-450 Porto, Portugal.
- Porto Biomechanics Laboratory (LABIOMEP), University of Porto, 4200-450 Porto, Portugal.
- Martial Arts and Combat Sports Research Group, Sport Department, School of Physical Education and Sport, University of São Paulo, São Paulo 05508-060, Brazil.
- Biomechanics Laboratory, School of Physical Education and Sport, University of São Paulo, São Paulo 05508-060, Brazil.
ORCID-Profile: Johan Robalino, Emerson Franchini, João Paulo Vilas-Boas, Bruno Mezêncio, Jacielle Carolina Ferreira
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Robalino, J., E Silva Cabral, A. L. C., Franchini, E., Goethel, M. F., Vilas-Boas, J. P., Mezêncio, B., & Ferreira, J. C. (2025). Assessing the Reliability of a Combat Sports Kick-Time Device. Sensors. https://doi.org/10.3390/s25051420
Vancouver
Robalino J, E Silva Cabral ALC, Franchini E, Goethel MF, Vilas-Boas JP, Mezêncio B, et al. Assessing the Reliability of a Combat Sports Kick-Time Device. Sensors. 2025. doi:10.3390/s25051420
BibTeX
@article{Robalino2025,
author = {Robalino, Johan and E Silva Cabral, Ana Luiza Costa and Franchini, Emerson and Goethel, Márcio Fagundes and Vilas-Boas, João Paulo and Mezêncio, Bruno and Ferreira, Jacielle Carolina},
title = {Assessing the Reliability of a Combat Sports Kick-Time Device},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25051420}
}
EUVIMED