EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing the Reliability of a Combat Sports Kick-Time Device

Johan Robalino iD, Ana Luiza Costa E Silva Cabral, Emerson Franchini iD, Márcio Fagundes Goethel, João Paulo Vilas-Boas iD, Bruno Mezêncio iD, Jacielle Carolina Ferreira iD

Sensors · 2025

DOI: 10.3390/s25051420 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Johan Robalino und 6 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate Program in Physical Education, Federal University of Mato Grosso, Cuiabá 78060-900, Brazil. Hauptthemen laut MEDLINE: Athletic Performance, Martial Arts. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In combat sports, precise technique evaluation is crucial for performance optimization; however, traditional systems for evaluating kick performance are frequently unreasonably complicated and costly. This study offers a useful and accessible substitute by introducing a contact mat-based tool that measures the roundhouse kick’s execution time during both the attack and recovery phases and by demonstrating its reliability. The experimental sessions involved 16 male Shotokan karate athletes (age: 25.6 ± 7.1 years; height: 1.74 ± 0.05 m; body mass: 71.5 ± 8.7 kg; body fat percentage: 14.7 ± 6.7%; training experience: 11.0 ± 4.9 years). The protocol included four sessions, starting with a familiarization phase followed by three testing sessions (test, retest, and retest two), during which a standardized warm-up was performed along with the roundhouse kick test. The intraclass coefficient correlation (ICC) used indicated high reliability for the at-tack (ICC = 0.85, 95% CI [0.64, 0.94]), recovery (ICC = 0.89, 95% CI [0.75, 0.96]), and total time (ICC = 0.90, 95% CI [0.76, 0.96]). The Friedman test revealed no significant difference between testing sessions (p > 0.31), demonstrating high reliability and no significant differences between sessions. This study confirms the system as a simple and reliability tool for measuring roundhouse-kick timing in combat sports.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Athletic PerformanceMartial ArtsHumansMaleAdultReproducibility of ResultsYoung AdultAthletes

Stichwörter der Autor:innen

Arduinobiomechanicscontact matkarateperformance assessmentroundhouse kicksports technology

Autor:innen und Institutionen

  • Postgraduate Program in Physical Education, Federal University of Mato Grosso, Cuiabá 78060-900, Brazil.
  • Centre for Research, Education, Innovation and Intervention in Sport (CIFI2D), Faculty of Sports, University of Porto, 4200-450 Porto, Portugal.
  • Porto Biomechanics Laboratory (LABIOMEP), University of Porto, 4200-450 Porto, Portugal.
  • Martial Arts and Combat Sports Research Group, Sport Department, School of Physical Education and Sport, University of São Paulo, São Paulo 05508-060, Brazil.
  • Biomechanics Laboratory, School of Physical Education and Sport, University of São Paulo, São Paulo 05508-060, Brazil.

ORCID-Profile: Johan Robalino, Emerson Franchini, João Paulo Vilas-Boas, Bruno Mezêncio, Jacielle Carolina Ferreira

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Zitieren

APA

Robalino, J., E Silva Cabral, A. L. C., Franchini, E., Goethel, M. F., Vilas-Boas, J. P., Mezêncio, B., & Ferreira, J. C. (2025). Assessing the Reliability of a Combat Sports Kick-Time Device. Sensors. https://doi.org/10.3390/s25051420

Vancouver

Robalino J, E Silva Cabral ALC, Franchini E, Goethel MF, Vilas-Boas JP, Mezêncio B, et al. Assessing the Reliability of a Combat Sports Kick-Time Device. Sensors. 2025. doi:10.3390/s25051420

BibTeX
@article{Robalino2025,
  author = {Robalino, Johan and E Silva Cabral, Ana Luiza Costa and Franchini, Emerson and Goethel, Márcio Fagundes and Vilas-Boas, João Paulo and Mezêncio, Bruno and Ferreira, Jacielle Carolina},
  title = {Assessing the Reliability of a Combat Sports Kick-Time Device},
  journal = {Sensors},
  year = {2025},
  doi = {10.3390/s25051420}
}
Kostenlos starten →