Surface-Imprinted Acrylamide Polymer-Based Reduced Graphene–Gold Sensor in Rapid and Sensitive Electrochemical Determination of αB-Conotoxin
Sensors · 2025
DOI: 10.3390/s25051408 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Jia Cao und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, School of Science, China Pharmaceutical University, Nanjing 211198, China. Hauptthemen laut MEDLINE: Graphite, Gold, Electrochemical Techniques, Acrylamide. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The quantitative determination of conotoxins has great potential in the development of natural marine peptide pharmaceuticals. Considering the time-consuming sample pretreatment and expensive equipment in MS or LC-MS/MS analysis, an electrochemical sensor combined with molecularly imprinted polymer (MIP) is fabricated for the rapid monitoring of conotoxin αB-VxXXIVA to promote its pharmaceutical value and eliminate the risk of human poisoning. Electrochemically reduced graphene oxide–gold composite (rGO-Au) is modified with chitosan (CS) and glutaraldehyde (GA) to immobilize the macromolecular peptide, conotoxin αB-VxXXIVA. Subsequently, acrylamide (AAM) with a cross-linking agent, N,N′-methylene-bisacrylamide (NNMBA), is introduced into the rGO-Au electrode to form MIPs by electro-polymerization. The proposed MIP-based electrochemical sensor, PAM/αB-CTX/CS-GA/rGO-Au/SPE, exhibits satisfactory sensing performance in the detection of αB-VxXXIVA. Based on current change versus logarithm concentration, a wide linear range from 0.1 to 10,000 ng/mL and a low detection limit (LOD) of 0.014 ng/mL for this sensor are obtained. This work provides a promising method in electrochemical determination combined with MIP for the determination of macromolecular peptides.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, School of Science, China Pharmaceutical University, Nanjing 211198, China.
ORCID-Profile: Fei Wang
Zitieren
APA
Cao, J., Li, J., Yu, T., & Wang, F. (2025). Surface-Imprinted Acrylamide Polymer-Based Reduced Graphene–Gold Sensor in Rapid and Sensitive Electrochemical Determination of αB-Conotoxin. Sensors. https://doi.org/10.3390/s25051408
Vancouver
Cao J, Li J, Yu T, Wang F. Surface-Imprinted Acrylamide Polymer-Based Reduced Graphene–Gold Sensor in Rapid and Sensitive Electrochemical Determination of αB-Conotoxin. Sensors. 2025. doi:10.3390/s25051408
BibTeX
@article{Cao2025,
author = {Cao, Jia and Li, Jiayue and Yu, Tianyang and Wang, Fei},
title = {Surface-Imprinted Acrylamide Polymer-Based Reduced Graphene–Gold Sensor in Rapid and Sensitive Electrochemical Determination of αB-Conotoxin},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25051408}
}