Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Qing Ge und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China. Hauptthemen laut MEDLINE: Skin, Blood Glucose, Regional Blood Flow. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
In non-invasive blood glucose measurement (NBGM) based on near-infrared spectroscopy, fluctuations in blood flow represent a primary source of interference. This paper proposes a local blood flow pre-stimulation method in which the local skin is heated to dilate blood vessels and increase blood flow. This approach aims to mitigate the impact of environmental temperature variations, emotional fluctuations, and insulin secretion on blood flow, thereby enhancing the accuracy of glucose measurement. To evaluate the effectiveness of this method, a blood flow interference experiment was conducted to compare the stability of the measured spectra with and without blood flow pre-stimulation. The results demonstrated that the pre-stimulation method presents good anti-interference capabilities. Furthermore, 45 volunteers underwent oral glucose tolerance tests (OGTTs) as a part of the validation experiments. In these tests, the forearm skin blood flow of 24 volunteers was pre-stimulated using elevated temperature, while the skin of the remaining 21 subjects was maintained at a natural temperature level without stimulation. The results indicate that compared to the non-stimulated condition, the correlation between the optical signal at 1550 nm and blood glucose levels was significantly enhanced under the pre-stimulation condition. Furthermore, the root mean square error (RMSE) of the linear prediction model was reduced to just 0.92 mmol/L. In summary, this paper presents a feasible blood flow control strategy that effectively stabilizes internal blood flow, thereby improving the accuracy of NBGM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin 300072, China.
- Sunrise Technology Co., Ltd., Tianjin 300192, China.
Zitieren
APA
Ge, Q., Han, T., Liu, X., Chen, J., Liu, W., Liu, J., & Xu, K. (2025). Effects of Skin Blood Flow Fluctuations on Non-Invasive Glucose Measurement and a Feasible Blood Flow Control Method. Sensors. https://doi.org/10.3390/s25041162
Vancouver
Ge Q, Han T, Liu X, Chen J, Liu W, Liu J, et al. Effects of Skin Blood Flow Fluctuations on Non-Invasive Glucose Measurement and a Feasible Blood Flow Control Method. Sensors. 2025. doi:10.3390/s25041162
BibTeX
@article{Ge2025,
author = {Ge, Qing and Han, Tongshuai and Liu, Xueying and Chen, Jiayu and Liu, Wenbo and Liu, Jin and Xu, Kexin},
title = {Effects of Skin Blood Flow Fluctuations on Non-Invasive Glucose Measurement and a Feasible Blood Flow Control Method},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25041162}
}
EUVIMED