Effects of Gait Rehabilitation Robot Combined with Electrical Stimulation on Spinal Cord Injury Patients’ Blood Pressure
Sensors · 2025
DOI: 10.3390/s25030984 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Takahiro Sato und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, Japan. Hauptthemen laut MEDLINE: Spinal Cord Injuries, Blood Pressure, Gait, Robotics. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS KAKENHI.
Abstract (Originalsprache)
Background
Orthostatic hypotension can occur during acute spinal cord injury (SCI) and subsequently persist. We investigated whether a gait rehabilitation robot combined with functional electrical stimulation (FES) stabilizes hemodynamics during orthostatic stress in SCI.
Methods
Six intermediate-phase SCI patients (five males and one female; mean age: 49.5 years; four with quadriplegia and two with paraplegia) participated. The participants underwent robotic training (RT), with a gait rehabilitation robot combined with FES, and tilt table training (TT). Hemodynamics were monitored using a laser Doppler flowmeter for the earlobe blood flow (EBF) and non-invasive blood pressure measurements. The EBF over time and the resting and exercise blood pressures were compared between each session. Adverse events were also evaluated.
Results
The EBF change decreased in TT but increased in RT at the 0.5-min slope (p = 0.03). Similarly, the pulse rate change increased in TT but decreased in RT at the 1-min slope (p = 0.03). Systolic and mean blood pressures were slightly higher in RT than in TT but not significantly (p = 0.35; 0.40). No adverse events occurred in RT, but two TT sessions were incomplete due to dizziness.
Conclusions
RT with FES can reduce symptoms during orthostatic stress in intermediate-phase SCI. Future studies require a larger number of cases to generalize this study.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Akita University Graduate School of Medicine, 1-1-1 Hondo, Akita 010-8543, Japan.
- Division of Rehabilitation Medicine, Akita University Hospital, 44-2, Hiroomote Hasunuma, Akita 010-8543, Japan.
- Department of Systems Design Engineering, Faculty of Engineering Science, Akita University Graduate School of Engineering Science, 1-1 Tegata Gakuen-cho, Akita 010-8502, Japan.
ORCID-Profile: Takahiro Sato, Ryota Kimura, Yuji Kasukawa, Daisuke Kudo, Kazuki Okura, Tomohiro Suda, Naohisa Miyakoshi
Förderung
- JSPS KAKENHI
Zitieren
APA
Sato, T., Kimura, R., Kasukawa, Y., Kudo, D., Hatakeyama, K., Watanabe, M., Takahashi, Y., Okura, K., Suda, T., Miyamoto, D., Iwami, T., & Miyakoshi, N. (2025). Effects of Gait Rehabilitation Robot Combined with Electrical Stimulation on Spinal Cord Injury Patients’ Blood Pressure. Sensors. https://doi.org/10.3390/s25030984
Vancouver
Sato T, Kimura R, Kasukawa Y, Kudo D, Hatakeyama K, Watanabe M, et al. Effects of Gait Rehabilitation Robot Combined with Electrical Stimulation on Spinal Cord Injury Patients’ Blood Pressure. Sensors. 2025. doi:10.3390/s25030984