Targetless Radar–Camera Extrinsic Parameter Calibration Using Track-to-Track Association

Xinyu Liu iD, Zhenmiao Deng iD, Gui Zhang

Sensors · 05.02.2025 · 25 (3) · 949

DOI: 10.3390/s25030949 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 05.02.2025. Verfasst von Xinyu Liu und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronics and Communication Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen 518107, China. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Science, Technology and Innovation Commission of Shenzhen Municipality, The Science and Technology Planning Project of Key Laboratory of Advanced IntelliSense Technology, Guangdong Science and Technology Department, Science, Technology and Innovation Commission of Shenzhen Municipality.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

One of the challenges in calibrating millimeter-wave radar and camera lies in the sparse semantic information of the radar point cloud, making it hard to extract environment features corresponding to the images. To overcome this problem, we propose a track association algorithm for heterogeneous sensors, to achieve targetless calibration between the radar and camera. Our algorithm extracts corresponding points from millimeter-wave radar and image coordinate systems by considering the association of tracks from different sensors, without any explicit target or prior for the extrinsic parameter. Then, perspective-n-point (PnP) and nonlinear optimization algorithms are applied to obtain the extrinsic parameter. In an outdoor experiment, our algorithm achieved a track association accuracy of 96.43% and an average reprojection error of 2.6649 pixels. On the CARRADA dataset, our calibration method yielded a reprojection error of 3.1613 pixels, an average rotation error of 0.8141°, and an average translation error of 0.0754 m. Furthermore, robustness tests demonstrated the effectiveness of our calibration algorithm in the presence of noise.

Schlagwörter

Stichwörter der Autor:innen

sensor fusiontargetless calibration

Autor:innen und Institutionen

  • School of Electronics and Communication Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen 518107, China.
  • School of Electronics and Communication Engineering, Sun Yat-sen University, Guangzhou 510275, China.
  • Dongguan Power Supply Bureau of Guangdong Power Grid Co., Ltd., Dongguan 523008, China.

ORCID-Profile: Xinyu Liu, Zhenmiao Deng

Förderung

  • The Science, Technology and Innovation Commission of Shenzhen Municipality
  • The Science and Technology Planning Project of Key Laboratory of Advanced IntelliSense Technology, Guangdong Science and Technology Department
  • Science, Technology and Innovation Commission of Shenzhen Municipality
  • Science and Technology Planning Project of Key Laboratory of Advanced IntelliSense Technology, Guangdong Science and Technology Department

Zitieren

APA

Liu, X., Deng, Z., & Zhang, G. (2025). Targetless Radar–Camera Extrinsic Parameter Calibration Using Track-to-Track Association. Sensors, 25(3), 949. https://doi.org/10.3390/s25030949

Vancouver

Liu X, Deng Z, Zhang G. Targetless Radar–Camera Extrinsic Parameter Calibration Using Track-to-Track Association. Sensors. 2025;25(3):949. doi:10.3390/s25030949

BibTeX
@article{Liu2025,
  author = {Liu, Xinyu and Deng, Zhenmiao and Zhang, Gui},
  title = {Targetless Radar–Camera Extrinsic Parameter Calibration Using Track-to-Track Association},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {3},
  pages = {949},
  doi = {10.3390/s25030949}
}
Kostenlos starten →