An Attomolar-Level Optical Device for Monitoring Receptor–Analyte Interactions Without Functionalization Steps: A Case Study of Cytokine Detection
Sensors · 2025
DOI: 10.3390/s25030930 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Nunzio Cennamo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering, University of Campania Luigi Vanvitelli, Via Roma 29, 81031 Aversa, Italy. Hauptthemen laut MEDLINE: Biosensing Techniques, Cytokines, Optical Devices. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
A plastic optical fiber (POF)-based device for biosensing strategies has been developed to monitor several protein–protein interactions at ultra-low concentrations without functionalization processes, exploiting plasmonic phenomena. In this work, novel tests were applied to different kinds of analyte–receptor interactions, such as interleukins, where the bioreceptor’s (protein antibody) molecular weight is roughly ten times that of the analyte (protein interleukin), while intracellular bioreceptors and small molecules at low molecular weight interactions have already been demonstrated via the same point-of-care test (POCT). The POCT was implemented by a white light source and a spectrometer connected via two POF-based chips connected in series: an innovative microcuvette chip and a D-shaped POF surface plasmon resonance (SPR) probe. In particular, the POF microcuvette chip was achieved by drilling three micro holes in the core of a modified POF. Instead of performing a functionalization step, the micro holes were filled with a specific receptor solution for the analyte (one microliter at the femtomolar level), which selectively captured the target (e.g., cytokine) when the samples were dropped over the filled micro holes (twenty microliters at the attomolar level). Three interleukins, IL-1β, IL-17A, and IL-18, were detected in the attomolar concentrations range by monitoring the resonance wavelength shift over time due to the cytokine/antibody (protein–protein) interaction. The POF-based device was proven to be effective for detecting several interleukins at the attomolar level in a few minutes and without functionalization processes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Engineering, University of Campania Luigi Vanvitelli, Via Roma 29, 81031 Aversa, Italy.
- Optosensing Srl, Via Carlo de Marco 69F, 80137 Naples, Italy.
- Berne Cardiovascular Research Center and Division of Cardiovascular Medicine, University of Virginia, Charlottesville, VA 22908, USA.
ORCID-Profile: Nunzio Cennamo, Francesco Arcadio, Rosalba Pitruzzella, Mimimorena Seggio, Maria Pesavento, Antonio Abbate, Luigi Zeni
Zitieren
APA
Cennamo, N., Arcadio, F., Marzano, C., Pitruzzella, R., Seggio, M., Pesavento, M., Toldo, S., Abbate, A., & Zeni, L. (2025). An Attomolar-Level Optical Device for Monitoring Receptor–Analyte Interactions Without Functionalization Steps: A Case Study of Cytokine Detection. Sensors. https://doi.org/10.3390/s25030930
Vancouver
Cennamo N, Arcadio F, Marzano C, Pitruzzella R, Seggio M, Pesavento M, et al. An Attomolar-Level Optical Device for Monitoring Receptor–Analyte Interactions Without Functionalization Steps: A Case Study of Cytokine Detection. Sensors. 2025. doi:10.3390/s25030930
BibTeX
@article{Cennamo2025,
author = {Cennamo, Nunzio and Arcadio, Francesco and Marzano, Chiara and Pitruzzella, Rosalba and Seggio, Mimimorena and Pesavento, Maria and Toldo, Stefano and Abbate, Antonio and Zeni, Luigi},
title = {An Attomolar-Level Optical Device for Monitoring Receptor–Analyte Interactions Without Functionalization Steps: A Case Study of Cytokine Detection},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25030930}
}