Integrating an Extended-Gate Field-Effect Transistor in Microfluidic Chips for Potentiometric Detection of Creatinine in Urine
Sensors · 2025
DOI: 10.3390/s25030779 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Dhaniella Cristhina De Brito Oliveira und 4 weiteren Autor:innen. Beteiligte Einrichtung: Instituto de Química, Universidade Estadual de Campinas (UNICAMP), Campinas 13083-852, SP, Brazil. Hauptthemen laut MEDLINE: Creatinine, Transistors, Electronic, Biosensing Techniques, Lab-On-A-Chip Devices. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CAPES/Brazil, FAPESP/Brazil, CNPQ/Brazil.
Abstract (Originalsprache)
Monitoring creatinine levels in urine helps to recognize kidney dysfunction. In this research, we developed a photocurable membrane for the detection of serum creatinine. Using a system based on field-effect transistors, we carried out creatinine quantification in synthetic urine. The device was able to cover values between 3 and 27 mmol L−1. The current sensitivity was 0.8529 (mA)1/2 mmol−1 L with 91.8% linearity, with the LOD and LOQ being 5.3 and 17.5 mmol L−1, respectively. The voltage sensitivity was 0.71 mV mmol−1 L with a linearity of 96.2%, with the LOD and LOQ being 4.2 and 14.0 mmol L−1, respectively. These data were obtained under flow conditions. The system performed very well during the measurements, with a hysteresis of about 1.1%. Up to 90 days after manufacture, the sensor still maintained more than 70% of its initial response. Even when used periodically during the first week and then stored unused at −18 °C, it was able to maintain 96.7% of its initial response. The device used in the flow setup only had a useful life of three days due to membrane saturation, which was not reversible. In the interference test, the membrane was also shown to respond to the urea molecule, but in a different response window, which allowed us to discriminate urea in synthetic urine. EGFETs can be used to identify variations in the creatinine concentration in urine and can help in therapeutic decision-making.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Instituto de Química, Universidade Estadual de Campinas (UNICAMP), Campinas 13083-852, SP, Brazil.
ORCID-Profile: Dhaniella Cristhina De Brito Oliveira, José Alberto Fracassi da Silva
Förderung
- CAPES/Brazil
- FAPESP/Brazil
- CNPQ/Brazil
Zitieren
APA
De Brito Oliveira, D. C., Costa, F. H. M., Beraldo, R. M., da Silva, J. A. F., & Diniz, J. A. (2025). Integrating an Extended-Gate Field-Effect Transistor in Microfluidic Chips for Potentiometric Detection of Creatinine in Urine. Sensors. https://doi.org/10.3390/s25030779
Vancouver
De Brito Oliveira DC, Costa FHM, Beraldo RM, da Silva JAF, Diniz JA. Integrating an Extended-Gate Field-Effect Transistor in Microfluidic Chips for Potentiometric Detection of Creatinine in Urine. Sensors. 2025. doi:10.3390/s25030779
BibTeX
@article{DeBritoOliveira2025,
author = {De Brito Oliveira, Dhaniella Cristhina and Costa, Fernando Henrique Marques and Beraldo, Renato Massaroto and da Silva, José Alberto Fracassi and Diniz, José Alexandre},
title = {Integrating an Extended-Gate Field-Effect Transistor in Microfluidic Chips for Potentiometric Detection of Creatinine in Urine},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25030779}
}
EUVIMED