The Application of Integrated Force and Temperature Sensors to Enhance Orthotic Treatment Monitoring in Adolescent Idiopathic Scoliosis: A Pilot Study
Sensors · 2025
DOI: 10.3390/s25030686 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2025. Verfasst von Yiying Zou und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China. Hauptthemen laut MEDLINE: Scoliosis, Orthotic Devices. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Orthosis-wearing compliance is crucial for achieving positive treatment outcomes in patients with adolescent idiopathic scoliosis (AIS), for whom 23 h of daily wear is typically prescribed. However, self-reported compliance is subjective and often based on patients’ memory, leading to inaccuracies. While portable electronic devices have been developed to objectively monitor compliance, relying solely on temperature or force data can be insufficient. This study introduced a novel method that integrated both force and temperature data to estimate orthosis-wearing compliance. Twelve patients (eight females and four males) diagnosed with moderate AIS were included. Each patient was prescribed a thoracic-lumbar-sacral orthosis equipped with an integrated force and temperature sensor system. After one month of orthotic treatment, self-reported wear time averaged 17.8 ± 6.2 h/day, while the sensor indicated an average wear time of 13.3 ± 5.0 h/day. Most patients overestimated their compliance. Nighttime was the most common period for orthosis wear (6.1 h/day), whereas compliance during school hours (2.8 h/day) and after-school hours (3.7 h/day) was lower. The integration of force and temperature sensors provides a more comprehensive understanding of orthosis compliance. Future studies with larger samples and longer monitoring periods are needed to investigate the correlation between compliance and treatment outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China.
- Department of Health Sciences and Technology, ETH Zurich, 8092 Zurich, Switzerland.
- Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB T6G 1H9, Canada.
ORCID-Profile: Yiying Zou, Jinhao Wang, Edmond Lou, Man-Sang Wong
Zitieren
APA
Zou, Y., Zhou, L., Wang, J., Lou, E., & Wong, M. S. (2025). The Application of Integrated Force and Temperature Sensors to Enhance Orthotic Treatment Monitoring in Adolescent Idiopathic Scoliosis: A Pilot Study. Sensors. https://doi.org/10.3390/s25030686
Vancouver
Zou Y, Zhou L, Wang J, Lou E, Wong MS. The Application of Integrated Force and Temperature Sensors to Enhance Orthotic Treatment Monitoring in Adolescent Idiopathic Scoliosis: A Pilot Study. Sensors. 2025. doi:10.3390/s25030686
BibTeX
@article{Zou2025,
author = {Zou, Yiying and Zhou, Lejun and Wang, Jinhao and Lou, Edmond and Wong, Man-Sang},
title = {The Application of Integrated Force and Temperature Sensors to Enhance Orthotic Treatment Monitoring in Adolescent Idiopathic Scoliosis: A Pilot Study},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25030686}
}
EUVIMED