Vergleichsstudie in der Zeitschrift Sensors, 2025. Verfasst von Seonghyun Kang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Korea University College of Medicine, Seoul 02841, Republic of Korea. Hauptthemen laut MEDLINE: Joint Instability, Ankle Joint, Foot Orthoses. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Health and Welfare, Ministry of Health and Welfare, Republic of Korea.
Abstract (Originalsprache)
Chronic ankle instability (CAI), due to its chronic nature and biomechanical complexity, is well-suited for continuous monitoring and tele-rehabilitation using wearable sensor technology. This study assessed whether a smart insole system, equipped with 4 force-sensing resistor sensors and an inertial measurement unit, combined with functional tests and biomechanical indices, could distinguish CAI patients from healthy controls. A total of 21 CAI patients (23.8 ± 5.1 years) and 16 controls (22.62 ± 2.60 years) completed a battery of functional performance tests while wearing the smart insole system. The results showed an increased medial-lateral pressure ratio in the CAI during heel raise (p = 0.031, effect size = 0.82) and hop tests, suggesting an everted foot position. Significant deviations in center-of-pressure trajectory during double-leg heel raises (p = 0.005, effect size = 1.10) suggested asymmetric motion coordination, while compensatory fluctuations of the lifted limb during single-leg balance tests (p = 0.011, effect size = 1.03) were greater in CAI patients. These findings facilitated the development of features to characterize CAI-specific movement patterns. Together, this system shows promise as a quantitative assessment tool for CAI, supporting improved treatment outcomes through tele-rehabilitation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Korea University College of Medicine, Seoul 02841, Republic of Korea.
- Department of Orthopaedic Surgery, Korea University Guro Hospital, Seoul 08308, Republic of Korea.
ORCID-Profile: Seonghyun Kang, Jaewook Kim, Yekwang Kim, Juhui Moon, Hak Jun Kim, Seung-Jong Kim
Förderung
- Ministry of Health and Welfare
- Ministry of Health and Welfare, Republic of Korea
Zitieren
APA
Kang, S., Kim, J., Kim, Y., Moon, J., Kim, H. J., & Kim, S. J. (2025). Application of Smart Insoles in Assessing Dynamic Stability in Patients with Chronic Ankle Instability: A Comparative Study. Sensors. https://doi.org/10.3390/s25030646
Vancouver
Kang S, Kim J, Kim Y, Moon J, Kim HJ, Kim SJ. Application of Smart Insoles in Assessing Dynamic Stability in Patients with Chronic Ankle Instability: A Comparative Study. Sensors. 2025. doi:10.3390/s25030646
BibTeX
@article{Kang2025,
author = {Kang, Seonghyun and Kim, Jaewook and Kim, Yekwang and Moon, Juhui and Kim, Hak Jun and Kim, Seung-Jong},
title = {Application of Smart Insoles in Assessing Dynamic Stability in Patients with Chronic Ankle Instability: A Comparative Study},
journal = {Sensors},
year = {2025},
doi = {10.3390/s25030646}
}
EUVIMED