Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry

Raghda Al-Halawani iD, Meha Qassem, Panicos A Kyriacou iD

Sensors · 19.01.2025 · 25 (2) · 559

DOI: 10.3390/s25020559 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Sensors, online erschienen am 19.01.2025. Verfasst von Raghda Al-Halawani und 2 weiteren Autor:innen. Beteiligte Einrichtung: Research Centre for Biomedical Engineering, City St George's, University of London, London, EC1V 0HB, UK. Hauptthemen laut MEDLINE: Melanins, Oximetry. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Over the past ten years, there has been an increasing demand for reliable consumer wearables as users are inclined to monitor their health and fitness metrics in real-time, especially since the COVID-19 pandemic. Reflectance pulse oximeters in fitness trackers and smartwatches provide convenient, non-invasive SpO2 measurements but face challenges in achieving medical-grade accuracy, particularly due to difficulties in capturing physiological signals, which may be affected by skin pigmentation. Hence, this study sets out to investigate the influence of skin pigmentation, particularly in individuals with darker skin, on the accuracy and reliability of SpO2 measurement in consumer wearables that utilise reflectance pulse oximeters. A Monte Carlo model is developed to assess the effect on simulated reflectance pulse oximetry measurements across light, moderate, and dark skin types for oxygen saturation levels between 70 and 100%. The results indicate that a one-algorithm-fits-all calibration approach may be insufficient, and root mean square errors (RMSEs) of at least 0.3956%, 0.9132%, and 8.4111% for light, moderate, and dark skin are observed when compared to transmittance calibration algorithms. Further research is required to validate these findings and improve the performance of reflectance pulse oximeters in real-world applications, particularly in the context of consumer wearables.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MelaninsOximetryHumansAlgorithmsCOVID-19LightMonte Carlo MethodOxygenOxygen SaturationSARS-CoV-2SkinSkin PigmentationWearable Electronic Devices

Stichwörter der Autor:innen

Monte Carlo simulationoxygen saturationphotoplethysmographypulse oximetryskin pigmentation

Substanzen

MelaninsOxygen

Autor:innen und Institutionen

  • Research Centre for Biomedical Engineering, City St George's, University of London, London, EC1V 0HB, UK.

ORCID-Profile: Raghda Al-Halawani, Panicos A Kyriacou

Zitieren

APA

Al-Halawani, R., Qassem, M., & Kyriacou, P. A. (2025). Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry. Sensors, 25(2), 559. https://doi.org/10.3390/s25020559

Vancouver

Al-Halawani R, Qassem M, Kyriacou PA. Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry. Sensors. 2025;25(2):559. doi:10.3390/s25020559

BibTeX
@article{AlHalawani2025,
  author = {Al-Halawani, Raghda and Qassem, Meha and Kyriacou, Panicos A},
  title = {Monte Carlo Simulation of the Effect of Melanin Concentration on Light–Tissue Interactions in Reflectance Pulse Oximetry},
  journal = {Sensors},
  year = {2025},
  volume = {25},
  number = {2},
  pages = {559},
  doi = {10.3390/s25020559}
}